已核实 DOI 相关产品: 3

In Situ Growth of Dopamine on QCM for Humidity Detection

Journal 2022 · IF 4.229 · 10(12): 522 · 发表于 2022 年 12 月 8 日
作者: Pengjia Qi,Ziwei Xu,Tong Zhang
阅读全文 在 PubMed 查看

摘要

Polydopamine (PDA) films were successfully prepared on quartz crystal microbalance (QCM) by in-situ growth method, and the obtained QCM sensor was used for humidity detection. Fourier transform infrared spectroscopy (FT-IR) and scanning electron microscopy (SEM) were used to study the chemical composition and microstructure of the in-situ grown PDA sensitive films. The experimental results showed that the PDA-QCM humidity sensor with 2 h polymerization growth times (2-PDA-QCM) owned high sensitivity (20.77 Hz/% RH), good selectivity, short response/recovery time (5 s/11 s) and acceptable long-term stability. In addition, the energy loss of the sensors fabricated under different conditions was investigated by impedance analysis. Based on all the test results, it is concluded that the combination of in-situ growth method and QCM can produce a room temperature humidity sensor with excellent performance.Keywords:quartz crystal microbalance;in-situ growth;polydopamine;humidity detection

本研究中使用的阿拉丁产品

3 款产品在本文中被引用