已核实 DOI PubMed 相关产品: 69

Reversible detection of Hg(II) in pure water based on thymine modified nitrogen, sulfur co-doped carbon dots combined with antidote

Journal 2022 · IF 4.831 · 发表于 2022 年 10 月 19 日
作者: Min Chen,Jun Wang,Qianbo Zhang,Jinsheng Zhang,Zhiming Chen,Rongguo Sun
阅读全文 在 PubMed 查看

摘要

Conventional Hg 2+ visual sensors are unsustainable, hindering their practical application for improved water quality and health. In order to address this challenge, herein, N, S co-doped carbon nanodots (NS-CDs) were prepared and well characterized, presented the fluorescent monitoring for Hg 2+ over other metal ions with the limit of detection (LOD) of 0.47 µM. Next, the CDs were successfully modified by thymine without any fluorescence labelling (referred to as T-NS-CDs). The sensitivity to Hg 2+ cloud be noticeable enhanced due to the formation of T-Hg 2+ -T specific base pairs. Accordingly, the LOD was calculated with values as low as 1.56 nM. Furthermore, Hg 2+ could be released and complexed with antidote (meso-2,3-dimercaptosuccinic acid) (DMSA-Hg 2+ ), being the responsible for the reversible interconversion between T-Hg 2+ -T and DMSA-Hg 2+ . Interestingly, the proposed sensing system also applies to the fluorescent sensing for Hg 2+ in tap water with satisfactory recoveries (96.97 %–101.38 %, RSD < 2 %). Thus, by simply combination of elemental doping and surface functionalization, the surface state and functionalities of CDs could be tailorable, endowing the fluorometric sensing towards Hg 2+ in environmental system.

本研究中使用的阿拉丁产品

69 款产品在本文中被引用