Molecularly imprinted electrochemical luminescence sensor based on core–shell magnetic particles with ZIF-8 imprinted material

Journal 2020 · IF 7.1 · 发表于 2020 年 12 月 25 日
作者: Peihong Tong,Yongjuan Meng,Junyu Liang,Jianping Li
阅读全文 在 PubMed 查看

摘要

A molecularly imprinted electrochemiluminescence (MIP-ECL) sensor with high sensitivity and good structural stability was constructed using the new composite material ZIF-8-NH 2 as an imprinted membrane. The ZIF-8-NH 2 imprinted composite material was prepared through layer-by-layer self-assembly with carboxyl functionalized magnetic CoFe 2 O 4 nanoparticles as the carrier, ZIF-8-NH 2 precursor as the functional monomer, and cinchonine (CCN) as the template molecule. The ZIF-8 MIP@Au@CoFe 2 O 4 core–shell imprinted material was characterized using infrared spectrometry, scanning electron microscopy and X-ray diffraction, and the recognition performance of molecularly imprinted sensor was characterized through electrochemical impedance spectroscopy and electrochemiluminescence (ECL) method. When CCN was re-adsorbed by the imprinted membrane, the ECL intensities of the MIP sensor increased because CCN molecules can promote the ECL intensity of Ru(bpy) 3 2+ . As a result, the MIP sensor showed preeminent linear response to CCN in the range of 1.0 × 10 −12 – 3.1 × 10 −8 mol/L, with a detection limit of 7.0 × 10 −13 mol/L, which is much lower than that reported for other detection methods. The sensor shows good practicality and can be used to detect CCN in human serum with recoveries ranging from 96.0%–103.0%.