已核实 DOI PubMed 相关产品: 0

In-situ synthesis of carbon dots-embedded europium metal-organic frameworks for ratiometric fluorescence detection of Hg2+ in aqueous environment

Journal 2020 · IF 5.977 · 发表于 2020 年 10 月 19 日
作者: Hao Guo,Xiaoqiong Wang,Ning Wu,Mengni Xu,Mingyue Wang,Longwen Zhang,Wu Yang
阅读全文 在 PubMed 查看

摘要

A novel dual-emission ratiometric fluorescent sensor (CDs@Eu-MOFs) has been synthesized successfully by encapsulating water-soluble fluorescent CDs into the chambers of Eu-MOFs via a simple one-pot hydrothermal method , which can be used for the detection of Hg 2+ in environmental water samples. The synthesized CDs@Eu-MOFs inherited simultaneously the excellent luminescence performance of Eu 3+ and CDs and exhibited good structural and fluorescence stability in aqueous solution. The presence of Hg 2+ changed the fluorescence intensity of CDs, while the fluorescence intensity of Eu-MOFs hardly changed, which could be used as the recognition part and the reference part respectively to construct the ratiometric fluorescence sensor. The obtained Hg 2+ fluorescent probe showed a wide linear range (0–300 μM) and a low detection limit (0.12 nM). The developed method can be used as a multi-functional fluorescent sensor with high sensitivity and good selectivity for the determination of Hg 2+ in actual water samples.