已核实 DOI PubMed 相关产品: 5

Surface molecularly imprinted polymer based on core-shell Fe3O4@MIL-101(Cr) for selective extraction of phenytoin sodium in plasma

Journal 2020 · IF 5.977 · 发表于 2020 年 7 月 17 日
作者: Mengtian Jia,Yanyan Zhu,Dong Guo,Xiaogang Bi,Xiaohong Hou
阅读全文 在 PubMed 查看

摘要

Core-shell magnetic Fe 3 O 4 @MIL-101(Cr) nanoparticles were synthesized via layer-by-layer self-assembly method. Using Fe 3 O 4 @MIL-101(Cr) as support, Fe 3 O 4 @MIL-101(Cr)@MIP was prepared with phenytoin as template, acrylamide as functional monomer , ethylene glycol dimethacrylate as cross-linker, methanol and acetonitrile as porogen , azoisobutyronitrile as initiator. The materials were characterized by a serious of characterization experiments. The prepared Fe 3 O 4 @MIL-101(Cr)@MIP was demonstrated to possess good separability, large adsorption capability, excellent adsorption selectivity , good durability and reusability via adsorption experiments. Subsequently, a magnetic solid phase extraction method (MSPE) based on Fe 3 O 4 @MIL-101(Cr)@MIP combined with high performance liquid chromatography-ultraviolet detector (HPLC-UV) was established for the determination of phenytoin sodium in plasma samples. Experimental parameters including pH, the amount of adsorbent, extraction time, elution conditions, the concentration of NaCl were investigated to optimize extraction process. The method was validated. The linearity was observed in the range of 0.05–40 μg mL −1 with a lower limit of quantification of 0.05 μg mL −1 . The calibration equations were y = 0.2514x + 0.0319 ( r 2  = 0.9938), y = 0.2888x + 0.0472 ( r 2  = 0.9943), y = 0.2565x + 0.0418 ( r 2  = 0.9976), respectively. The recoveries ranged from 89.2 to 94.3%, intra- and inter-day precision (RSDs) ranged from 2.1 to 9.7% and 2.9–9.2%, respectively. The established MSPE-HPLC-UV method was time-saving, sensitive, accurate, environmental friendly, and drastically reduced the complex matrix interferences. The established method was successfully applied for phenytoin sodium determination in real plasma samples, providing new directions for therapeutic drug monitoring.

本研究中使用的阿拉丁产品

5 款产品在本文中被引用