Rapid and label-free optical assay of S-layer protein with high sensitivity using TiO2-coated porous silicon-based microfluidic biosensor

Journal 2020 · IF 7.1 · 发表于 2020 年 6 月 30 日
作者: Siqi Zhuo,Mingyue Xun,Mingda Li,Xiaoxue Kong,Rui Shao,Tiesong Zheng,Daodong Pan,Jianlin Li,Qianjin Li
阅读全文 在 PubMed 查看

摘要

S-layer protein (SLP) is a surface protein present in many bacteria and shows unique self-assemble ability for various applications, but its detection methods are very limited. In this paper, a label-free, highly selective and sensitive assay of SLP was developed by using the TiO 2 -coated porous silicon (PSi)-based microfluidic biosensor. The PSi-based biosensor could be easily prepared in a microfluidic device to build a microfluidic biosensing system for measuring SLP in samples rapidly. As the detection principle of the biosensor was based on the light reflection interference, so there was no labeling requirement. The specific recognition capability of the PSi-based biosensor was achieved by the non-covalently immobilized anti-SLP on the PSi surface. The developed biosensing system showed a rapid response time (5 min) and an excellent specificity to SLP, and displayed a broad detection linear range of 0.001 ∼ 10 μg/mL and a low detection limit of 3.2 ± 1.7 × 10 −5 μg/mL (0.70 ± 0.37 pM). The microfluidic biosensor can also be used for determination of the apparent dissociation constant ( K d ) between SLP and anti-SLP, which was measured to be 4.8 ± 0.9 × 10 -9 M.

本研究中使用的阿拉丁产品

46 款产品在本文中被引用