已核实 DOI 相关产品: 5

Preparation of W1/O/W2 emulsion to limit the diffusion of Fe3+ in the Fricke gel 3D dosimeter

Journal 2020 · IF 2.578 · 31(10): 2127-2135 · 发表于 2020 年 4 月 26 日
作者: Wei Zhang,Kaikai Wang,Xiaodan Hu,Xiaohong Zhang,Shuquan Chang,Haiqian Zhang
阅读全文 在 PubMed 查看

摘要

The irradiation of tumors in radiotherapy requires accurate 3D dosimetry. The Fricke 3D dosimeters, which were considered to be high potential of application in 3D dosimetry, suffer from a reduced temporal integrity of dose distribution caused by Fe 3+ ions diffusion. To overcome the drawback, we firstly synthesized a kind of amphiphilic molecules with critical micelle concentration of 0.45 g/L and hydrophile-lipophile balance value of 10, then prepared multiple emulsions by self-assembling those molecules in Fricke solution under liquid paraffin, and finally obtained Fricke hydrogel embedded with the multiple emulsions. The diffusion coefficient of Fe 3+ ions in the embedded Fricke hydrogel was measured to be 0.17 mm 2 /h. The hydrogel dosimeter exhibits considerable potential for use in dose verification applications.

本研究中使用的阿拉丁产品

5 款产品在本文中被引用