已核实 DOI PubMed 相关产品: 53

Colorimetric immunoassay for human chorionic gonadotropin by using peroxidase-mimicking MnO2 nanorods immobilized in microplate wells

Journal 2019 · IF 5.479 · 186(8): 1-9 · 发表于 2019 年 7 月 27 日
作者: Zhang Zhi,Xu Guoli,Xie Li,Guan Yueping
阅读全文 在 PubMed 查看

摘要

A colorimetric immunoassay is described for the pregnancy marker human chorionic gonadotropin (HCG). The assay is based on the use of MnO 2 nanorods acting as a peroxidase mimic. The nanorods were prepared by a hydrothermal method using EDTA as a template. They exhibit excellent peroxidase-like activity and stability. The nanorods were immobilized in a chitosan matrix in the wells of a BSA-modified microplate which then were further modified with streptavidin and biotinylated capture antibodies. The specific recognition between HCG and the antibodies in wells inhibit the peroxidase-like activity of the nanorods. Hence, the substrate 3,3′,5,5′-tetramethylbenzidine is less efficiently catalytically oxidized by H 2 O 2 to form a blue colored product. This results in a decrease in the absorbance at 652 nm. Response is linear in the 0.5 to 400 mIU·mL −1 HCG concentration range, and the detection limit is 0.36 mIU·mL −1 under optimized conditions. The method is highly specific, acceptably reproducible and stable. It was applied to the determination of HCG concentration in serum samples, and results were in good agreement with data obtained by the reference method.” Schematic presentation of colorimetric immunoassay for human chorionic gonadotropin (HCG) by using MnO 2 nanorods with peroxidase-like activity immobilized in microplate wells. The specific recognition between HCG and the antibodies in wells inhibits the peroxidase-like activity of the nanorods. TMB: 3,3′,5,5′-tetramethylbenzidine.

本研究中使用的阿拉丁产品

53 款产品在本文中被引用