摘要
A metal organic framework (MOF)-polymer monolithic column was prepared by redox initiation using modified MOF and N -methylolacrylamide (NMA) as co-monomers. The obtained monolithic column was characterized by scanning electron microscopy (SEM) and nitrogen adsorption-desorption isotherm measurement. It was used as a solid phase extraction (SPE) absorbent for the online enrichment of ursolic acid (UA) by high performance liquid chromatography . The adsorption amount of UA on the monolith was compared with that of silica gel-C18 adsorbent and the monolith without MOF material. The MOF-polymer monolithic column showed high selectivity and good permeability. Under the optimum conditions for extraction and determination, the calibration equation was y = 79.854× + 0.1939; the linear range was 0.001–0.9 mg/mL; the linear regression coefficient was 0.9993; the limit of detection (LOD) and the limit of quantification (LOQ) were 0.17 μg/mL and 0.57 μg/mL, respectively; the inter-day and intra-day accuracies were <6.44%; the recovery was in the range of 86.52–105.26%. The MOF-polymer monolithic column was successfully used as SPE column for enrichment and determination of UA in Chinese herbal medicine.