Facile Preparation of Fe3O4/C Nanocomposite and Its Application for Cost-Effective and Sensitive Detection of Tryptophan

Journal 2019 · IF 4.694 · 9(6): 245 · 发表于 2019 年 6 月 22 日
作者: Jun Liu,Shuai Dong,Quanguo He,Suchun Yang,Mei Xie,Peihong Deng,Yonghui Xia,Guangli Li
阅读全文 在 PubMed 查看

摘要

In this study, we reported facile synthesis of Fe3O4/C composite and its application for the cost-effective and sensitive determination of tryptophan (Trp) in human serum samples. Fe3O4/C composites were prepared by a simple one-pot hydrothermal method followed by a mild calcination procedure, using FeCl3∙6H2O as Fe3O4precursor, and glucose as reducing agent and carbon source simultaneously. The Fe3O4/C composite modified glassy carbon electrode (Fe3O4/C/GCE) was prepared by drop-casting method. The microstructure and morphology of Fe3O4/C composite was characterized by powder X-ray diffraction (XRD) and scanning electron microscopy (SEM), respectively. Due to large specific surface area and synergistic effect from Fe3O4nanoparticles and carbon coating, Fe3O4/C composite showed excellent electrocatalytic activity toward the oxidation of Trp. As a result, the proposed Fe3O4/C/GCE displayed superior analytical performances toward Trp determination, with two wide detection ranges (1.0–80 μM and 80–800 μM) and a low detection limit (0.26 μM, S/N = 3). Moreover, successful detection of Trp in human serum samples further validate the practicability of the proposed sensor.Keywords:Fe3O4/C composite;tryptophan;voltammetric detection;second derivative linear scan voltammetry

本研究中使用的阿拉丁产品

7 款产品在本文中被引用