Fluorometric determination of ciprofloxacin using molecularly imprinted polymer and polystyrene microparticles doped with europium(III)(DBM)3phen

Journal 2019 · IF 5.479 · 186(6): 1-10 · 发表于 2019 年 5 月 7 日
作者: Li Zhuanying,Cui Zhimeng,Tang Yiwei,Liu Xiuying,Zhang Xuemei,Liu Bingxiang,Wang Xianghong,Draz Mohamed Shehata,Gao Xue
阅读全文 在 PubMed 查看

摘要

The authors describe a microparticle-based system for the detection of the fluoroquinolone antibiotic ciprofloxacin. The method is using the tris(dibenzoylmethane)(1,10-phenanthroline)europium(III) luminophore in polystyrene microparticles along with a molecularly imprinted polymer (MIP) for ciprofloxacin. If ciprofloxacin is captured by the MIP, it quenches the fluorescence of the luminophores. Fluorescence drops linearly in the 0.5–100 μg L −1 ciprofloxacin concentration range, and the detection limit is 92 ng L −1 . The method was applied to the analysis of fish samples to assess the analytical performance of the probe. Recoveries ranged from 85.4 to 86.6%, and relative standard deviations between 2.1 and 3.9% (for n  = 5). Schematic presentation of a microparticle-based probe using the tris(dibenzoylmethane)(1,10-phenanthroline)europium(III) luminophore in polystyrene particles along with a molecularly imprinted polymer for ciprofloxacin. After removal of template, carboxylic groups left in the probe can bind to ciprofloxacin through hydrogen bonds.