摘要
The degradation of roxithromycin (ROX) by hydroxyl radical (·OH) generated by UV/H 2 O 2 was systematically investigated in terms of degradation kinetics, effects of water chemistry parameters, oxidation products, as well as toxicity evaluation. The degradation of ROX by UV/H 2 O 2 with varying light irradiation intensity, initial ROX concentration, and H 2 O 2 concentration in pure water and wastewater all followed pseudo-first-order kinetics. The second-order rate constant for reaction between ROX and ·OH is 5.68 ± 0.34 × 10 9 /M/s. The degradation rate of ROX increased with the pH; for instance, the apparent degradation rates were 0.0162 and 0.0309/min for pH 4 and pH 9, respectively. The presence of natural organic matter (NOM) at its concentrations up to 10 mg C/L did not significantly affect the removal of ROX. NO 3 − and NO 2 − anions inhibited the degradation of ROX due to the consumption of ·OH in reactions with these ions. Fe 3+ , Cu 2+ , and Mg 2+ cations inhibited the degradation of ROX, probably because of the formation of ROX-metal chelates. A total of ten degradation products were tentatively identified by HPLC/LTQ-Orbitrap XL MS, which mainly derived from the attack on the oxygen linking the lactone ring and the cladinose moiety, tertiary amine and oxime side chain moiety by ·OH. The toxicity evaluation revealed that UV/H 2 O 2 treatment of ROX induced the toxicity to bioluminescent bacteria increased.