已核实 DOI PubMed 相关产品: 15

A highly stable black phosphorene nanocomposite for voltammetric detection of clenbuterol

Journal 2018 · IF 5.705 · 185(12): 1-10 · 发表于 2018 年 11 月 29 日
作者: Ge Yu,Camarada María Belén,Xu Lanjiao,Qu Mingren,Liang Huan,Zhao Erlong,Li Mingfang,Wen Yangping
阅读全文 在 PubMed 查看

摘要

A nanocomposite was prepared from graphene-like two-dimensional black phosphorene (BP, an allotrope of phosphorus) and nafion (Nf) treated with isopropanol (IP). A glassy carbon electrode (GCE) modified with this nanocomposite was found to be a viable sensor for voltammetric determination of clenbuterol (CLB). Unlike previously reported pure BP, the BP nanocomposite was stable towards water and oxygen. Its morphology, structure, electrochemically active surface area and electrochemical stability were investigated. The BP-Nf (IP) modified GCE displayed good electrochemical stability and electrocatalytic capacity with a low working potential of 0.94 V (vs. SCE), excellent peak current response for CLB in a linear concentration range of 0.06–24 μM with a detection limit of 3.7 nM (3σ/m) and a sensitivity of 0.14 μA·μM −1 ·cm −2 under optimal conditions. A sensing mechanism for the electro-oxidation of CLB was suggested and verified by density functional theory calculations under imitation of aqueous solution conditions. The sensor was successfully applied to the determination of CLB in bovine meat and bovine serum samples. Highly-stable black phosphorene (BP) nanocomposite based on Nafion (Nf) was used to modify a glassy carbon electrode (GCE). It is shonw to be a viable electrochemical platform for sensitive voltammetric determination of trace clenbuterol (CLB) in bovine beef and bovine serum.

本研究中使用的阿拉丁产品

15 款产品在本文中被引用