已核实 DOI 相关产品: 42

Electrochemical sensor for the determination of dimetridazole using a 3D Cu2O/ErGO-modified electrode

Journal 2018 · IF 2.073 · 10(27): 3380-3385 · 发表于 2018 年 6 月 21 日
作者: Xionghui Ma,Jianping Li,Jinhui Luo,Chunhua Liu,Shuhuai Li
阅读全文 在 PubMed 查看

摘要

A three-dimensional Cu2O/electrochemically reduced graphene (ErGO)-modified electrode was developed for the determination of dimetridazole. Cu2O/GO was initially prepared using a modified solvothermal method, and the 3D structure was constructed by electrodepositing a Cu2O/GO dispersion on a glassy carbon electrode in the presence of lithium perchlorate. The enhanced electrocatalytic reduction of dimetridazole was confirmed, and the electrochemical reduction reaction was found to be a typical adsorption-controlled process. Our results revealed that the response to dimetridazole was linear in the concentration range of 30–150 nmol L−1 and the detection limit was 3.64 nmol L−1. The prepared electrode was also employed to detect dimetridazole in an egg sample, thereby indicating its potential practical application.

本研究中使用的阿拉丁产品

42 款产品在本文中被引用