已核实 DOI PubMed 相关产品: 28

The detection of brucellosis antibody in whole serum based on the low-fouling electrochemical immunosensor fabricated with magnetic Fe3O4@Au@PEG@HA nanoparticles

Journal 2018 · IF 8.173 · 发表于 2018 年 6 月 6 日
作者: Shuli Lv,Jinliang Sheng,Shiyi Zhao,Mingchao Liu,Lihua Chen
阅读全文 在 PubMed 查看

摘要

It is a novel competitive challenge for electrochemical biosensor to directly, rapidly and ultrasensitively detect the disease markers in the whole serum due to biofouling caused by the complexity of actual samples. In this paper, poly (ethylene glycol) (PEG) and hyaluronic acid (HA) were utilized to modify Fe 3 O 4 @Au nanoparticles (NPs). Based on the successfully preparation and characterization of Fe 3 O 4 @ [email protected] @HA NPs with TEM , SEM, XRD, FTIR and EDS , respectively, a novel immunosensor of brucellosis with high selectivity , sensitivity and almost perfect protein-resistant properties in various external environments, especially, in complex biological systems was fabricated. More importantly, this immunosensor is capable of assaying brucellosis antibody in 100% serum without suffering from any significant biological interference. In addition, a wide linear response range from 10 –15 g mL −1 to 10 –11 g mL −1 towards antibody in 100% serum and a low limit of detection (LOD) of 0.36 fg mL −1 (3σ, n = 13) are demonstrated, which indicates that this immunosensor has a promising potential in clinical diagnosis.

本研究中使用的阿拉丁产品

28 款产品在本文中被引用