摘要
This paper described a novel, facile and nonenzymatic electrochemical biosensor to detect hydrogen peroxide (H 2 O 2 ). The sensor was fabricated based on Pd-Pt nanocages and SnO 2 /graphene nanosheets modified electrode (PdPt [email protected] /GCE). The electrochemical behavior of PdPt [email protected] /GCE exhibited excellent catalytic activity toward H 2 O 2 with fast response, high selectivity , superior sensitivity, low detection limit of 0.3 μM and large linear range from 1 μM to 300 μM. Under these obvious advantages, the constructed biosensor provided to be reliable for determination of H 2 O 2 secreted from human cervical cancer cells (Hela cells). Hence, the proposed biosensor is a promising candidate for detection of H 2 O 2 in situ released from living cells in clinical diagnostics.
危险品化学品经营许可证(带存储)