Electrochemical hydrogen peroxide sensor based on carbon supported Cu@Pt core-shell nanoparticles

Journal 2017 · IF 4.164 · 发表于 2017 年 4 月 14 日
作者: Wenjun Zhao,Jiayi Jin,Huimin Wu,Shengfu Wang,Chuanqi Fneg,Shuijin Yang,Yu Ding
阅读全文 在 PubMed 查看

摘要

The Cu@Pt/C nanocomposites have been synthesized via two-step reduction method. Electrochemical observations showed that the Cu@Pt/C had better electrocatalytic activity for the reduction of hydrogen peroxide than Pt/C, with a wide linear range between 0.50   μM and 32.56   mM, a high sensitivity of 351.3   μA   mM −   1   cm −   2 , and a low detection limit of 0.15   μM (signal/noise   =   3). Furthermore, the sensor based on Cu@Pt/C has potential applications due to its excellent long-time stability, good reproducibility and acceptable selectivity.

本研究中使用的阿拉丁产品

295 款产品在本文中被引用