Amperometric aptasensing of chloramphenicol at a glassy carbon electrode modified with a nanocomposite consisting of graphene and silver nanoparticles

Journal 2017 · IF 4.58 · 184(5): 1445-1451 · 发表于 2017 年 3 月 1 日
作者: Liu Shun,Lai Guosong,Zhang Haili,Yu Aimin
阅读全文 在 PubMed 查看

摘要

A nanocomposite prepared from reduced graphene oxide (rGO) and silver nanoparticles (AgNPs) is used in an electrochemical aptasensor for the sensitive and selective determination of the antibiotic chloramphenicol (CAP). The nanocomposite was obtained by electrostatic assembly of AgNPs on the surface of polyelectrolyte-functionalized rGO and then used to modify a glassy carbon electrode. The biosensor is then obtained by immobilizing the aptamer against CAP. When incubated with solutions of CAP, the sensor surface is loaded with CAP due to aptamer recognition. The captured CAP can be electrochemically reduced to yield a current that is strongly enhanced as a result of the excellent electrocatalysis property of the graphene/AgNP-nanocomposite. Under optimum conditions, the calibration plot is linear in the 0.01 to 35 μM concentration range, with a 2 nM detection limit (at 3σ). The sensor is reproducible, stable, selective over homologous interferents, and performs excellently when analyzing CAP in milk samples. A graphene/silver nanoparticle-based electrochemical aptasensor is designed for the selective determination of the antibiotic chloramphenicol (CAP). The excellent electrocatalytic reduction of CAP specifically captured onto the electrode surface enables the sensitive electrochemical signal transduction of the biosensor by linear sweep voltammetry (LSV).

本研究中使用的阿拉丁产品

18 款产品在本文中被引用