Determination of catechol and hydroquinone with high sensitivity using MOF-graphene composites modified electrode

Journal 2017 · IF 3.012 · 发表于 2017 年 2 月 20 日
作者: Qi Chen,Xi Li,Xinmin Min,Dan Cheng,Jian Zhou,Yugang Li,Zhizhong Xie,Peng Liu,Weiquan Cai,Chaocan Zhang
阅读全文 在 PubMed 查看

摘要

A composite (MOF-GO) of Cu-based MOF-199 (MOF) and graphene oxide (GO) was prepared by the solvothermal method and used as the modified material to fabricate an electrochemical sensor for the determination of catechol (CT) and hydroquinone (HQ). The modification was carried out through the electrodeposition of MOF-GO composites on the glassy carbon electrode and the transformation of MOF-GO to MOF-ERGO by an electrochemical reduction . Differential pulse voltammetry (DPV) was employed for exploring the electrochemical properties of the as-prepared electrode and the oxidation of CT and HQ at the modified electrode . Under the optimized experimental condition, the linear calibration curve was obtained in the range from 0.1   μM to 566   μM for CT ( R 2   =   0.997) and 0.1   μM to 476   μM for HQ ( R 2   =   0.999) with the same low detection limit of 0.1   μM ( S / N   =   3). The experimental results showed that the modified electrode was easily fabricated in control and exhibited the outstanding stability. The validity for practical samples detection of CT and HQ was also demonstrated with satisfactory results.

本研究中使用的阿拉丁产品

2 款产品在本文中被引用