已核实 DOI PubMed 相关产品: 132

Ultrasensitive detection of clenbuterol by a covalent imprinted polymer as a biomimetic antibody

Journal 2017 · IF 4.529 · 发表于 2017 年 1 月 20 日
作者: Yiwei Tang,Jingwen Gao,Xiuying Liu,Xue Gao,Tao Ma,Xiaonan Lu,Jianrong Li
阅读全文 在 PubMed 查看

摘要

As an ideal biomimetic antibody, molecularly imprinted polymer (MIP) has shown great promise in immunoassays. Here, we developed a covalent imprinting method to prepare MIP artificial antibody towards clenbuterol on the well surface of a microtiter plate. Template molecule (clenbuterol) was splited by hydrolysis with functional monomer and removed by methanol/acetic acid solution, and then three-dimensional cavities were fabricated in the MIP, which can rebind template molecule via hydrogen bond interaction. Using this artificial antibody, we developed a novel biomimetic enzyme-linked immunosorbent assay (ELISA) with excellent sensitivity and specificity. The linear range for clenbuterol was 10 −5 to 1000   μg   L −1 , with a detection limit of 10 −7   μg   L −1 . Cross reactivity of this MIP artificial antibody to other four structural analogs was less than 0.93%. This method was applied to determine clenbuterol in real samples with satisfactory result, suggesting a promising application of the biomimetic ELISA in food and environmental analysis.

本研究中使用的阿拉丁产品

132 款产品在本文中被引用