已核实 DOI 相关产品: 15

A non-enzymatic electrochemical biosensor based on SiO2–Au nanoparticles for hemoglobin detection

Journal 2017 · IF 1.9 · 9(8): 1265-1272 · 发表于 2017 年 1 月 19 日
作者: Caihong Li,Jian Li,Haowei Tang,Xiaodi Yang,Qiqi Fei,Chong Sun
阅读全文 在 PubMed 查看

摘要

In this study, a simple non-enzymatic hemoglobin (Hb) biosensor based on SiO2–Au nanoparticles (SiO2–Au NPs) was prepared and investigated. The structure and morphology of the SiO2–Au NPs were characterized by transmission electron microscopy (TEM) and UV-vis spectroscopy. Fourier transform infrared spectra (FTIR) and circular dichroism (CD) spectra were obtained to test the biocompatibility of the SiO2–Au NPs. The electrochemical properties were determined via cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), and differential pulse voltammetry (DPV). Under the optimized conditions, the linear regression equation between the peak currents and the concentration of Hb was i (μA) = −51.57269 + 83.14106c (mg mL−1) (R2 = 0.9979) with a detection limit of 204.46 ng mL−1. In addition, the electrochemical biosensor possessed good anti-interference performance. Due to the superior performance of SiO2–Au NPs, this method shows great potential applications for the direct sensing of Hb for the purpose of evaluating meat quality.

本研究中使用的阿拉丁产品

15 款产品在本文中被引用