已核实 DOI 相关产品: 2

Flow-based determination of methionine in pharmaceutical formulations exploiting TGA-capped CdTe quantum dots for enhancing the luminol-KIO4 chemiluminescence

Journal 2016 · IF 2.693 · 发表于 2016 年 11 月 11 日
作者: Min Zhou,Ailian Wang,Cong Li,Xiaowei Luo,Yongjun Ma
阅读全文 在 PubMed 查看

摘要

A novel flow-injection chemiluminescence method (FI-CL) was established for the determination of methionine in this paper, based on its strong enhancement on CL intensity of the luminol-KIO 4 system catalyzed by thioglycolic acid-capped CdTe quantum dots in alkaline media. Under the optimized conditions, the relative CL intensity was in proportion to methionine concentration in the range from 1.0×10 − 8 to 1.0×10 −5   g   mL −1 with a detection limit of 6.6×10 −9   g   mL −1 (3σ). The relative standard deviation (RSD) of the CL intensity for 1.0×10 −6   g   mL −1 standard methionine solution was 0.97% (n=11). The proposed method was successfully applied to determine methionine in commercial pharmaceutical formulations with recoveries between 98.0% and 101.9%. The possible CL mechanism was discussed as well.

本研究中使用的阿拉丁产品

2 款产品在本文中被引用