摘要
An elevated uric acid (UA) in urine or serum can affect renal function and blood pressure, which is an indicator of gout, cardiovascular and renal diseases, hypertension, etc. In this work, a new type of mixed matrix membrane (MMM), based on graphitic carbon nitrides (g-CNs) and hollow fiber (HF), was prepared and combined with solid phase microextraction (SPME) mode to determine UA in urine and serum followed by gas chromatography-mass spectrometry (GC/MS). The porous g-CNs were dispersed in ammonia, and then the exfoliated g-CNs nanosheets were held in the pores of HF by capillary forces and sonification. The prepared g-CNs modified HF (g-CNs-HF) was immersed in biofluid directly to extract UA with SPME mode and the solvent-free mode is convenient for further derivatization and analysis. To achieve the highest extraction efficiency (EF), main extraction and derivatization parameters, such as g-CNs-HF immobilizing time, sonification power and time of extraction, derivatization and desorption time, were optimized. Under the optimum extraction conditions, a favorable linearity of UA was obtained in the range 0.1–200 μg mL −1 with correlation coefficients higher than 0.9990, and the average recoveries at three spiked levels of UA in urine and serum ranged from 80.7% to 121.6%, from 84.7% to 101.1%, respectively. The obtained results demonstrated the developed g-CNs-HF-SPME is a simple, rapid, cost-effective, solvent-free method for the analysis of UA in biofluid.