摘要
A voltammetric sensor for hemoglobin (Hb) was prepared from molecularly imprinted polymer nanoparticles (MINPs) via electrophoretic deposition. A photo-sensitive copolymer composed of poly-γ-glutamic grafted with the fluorophore 7-amino-4-methylcoumarin was converted into nanoparticles that were imprinted with Hb. The resultant MINPs were then placed on a glassy carbon electrode (GCE) via electrophoretic deposition. Subsequent photo-crosslinking locks the recognition sites. The template was removed by extraction with a mixture of acetic acid and methanol at a ratio of 1:9 (v:v) to obtain a voltammetric sensor for Hb. The current response of the sensor at a working voltage of −260 mV is linearly related to the concentration of Hb in the range from 5 to 100 μg mL −1 , and recoveries range from 98.7 to 102.3 %. Compared to the respective non-imprinted nanoparticles, the sensor displays high recognition capability and affinity for Hb. A voltammetric sensor for hemoglobin (Hb) was prepared from molecularly imprinted polymer nanoparticles via electrophoretic deposition. The current response of the sensor is linearly related to the concentration of Hb in the range from 0.005 mg mL −1 to 0.1 mg mL −1 , and recoveries range from 98.7 to 102.3 %.
危险品化学品经营许可证(带存储)