已核实 DOI PubMed 相关产品: 18

Zeolite imidazolate framework-8 as sorbent for on-line solid-phase extraction coupled with high-performance liquid chromatography for the determination of tetracyclines in water and milk samples

Journal 2013 · IF 4.612 · 发表于 2013 年 6 月 29 日
作者: Xue-Qing Yang,Cheng-Xiong Yang,Xiu-Ping Yan
阅读全文 在 PubMed 查看

摘要

Zeolite imidazolate framework-8 (ZIF-8) was used as the novel sorbent for on-line solid-phase extraction coupled with high-performance liquid chromatography (HPLC) for the determination of oxytetracycline (OTC), tetracycline (TC) and chlorotetracycline (CTC) in water and milk samples. 390   mg of ZIF-8 was packed into a stainless steel column (3   cm long   ×   4.6   mm i.d.) which was mounted on the HPLC injector valve to replace the sample loop. On-line solid-phase extraction of OTC, TC and CTC was achieved by loading sample solution at a flow rate of 3.0   mL   min −1 for 10   min with the aid of a flow-injection system. The extracted analytes were subsequently eluted into a C 18 analytical column (25   cm long   ×   4.6   mm i.d.) for HPLC separation under isocratic condition with a mobile phase (10% MeOH–20% ACN–70% 0.02   mol   L −1 oxalic acid solution) at a flow rate of 1.0   mL   min −1 . Under optimized conditions, the developed method gave the enhancement factors of 35–61, the linearity range of 5–1000   μg   L −1 , the detection limits of 1.5–8.0   μg   L −1 , quantification limits of 5.0–26.7   μg   L −1 , uncertainties of 0.9–1.1   μg   L −1 , and the sample throughput of 4 samples h −1 . The recoveries of OTC, TC and CTC at 50   μg   L −1 in water and milk samples ranged from 70.3% to 107.4%.

本研究中使用的阿拉丁产品

18 款产品在本文中被引用