已核实 DOI 相关产品: 67

Electrochemical determination of nonylphenol using differential pulse voltammetry based on a graphene–DNA-modified glassy carbon electrode

Journal 2013 · IF 2.672 · 发表于 2013 年 6 月 13 日
作者: Lixuan Zeng,Aizhen Zhang,Xiaohua Zhu,Chuyi Zhang,Yong Liang,Junmin Nan
阅读全文 在 PubMed 查看

摘要

The electrochemical determination of nonylphenol (NP) using differential pulse voltammetry (DPV) is developed based on a reduced graphene–DNA hybrid-modified glassy carbon electrode (GR-DNA/GCE). The electrochemical oxidation of NP at the GR-DNA/GCE is shown to be an one-electron and one-proton process, and due to the synergic effect of GR and DNA , the GR-DNA/GCE has 4.87, 2.76 and 2.09 times higher current response than bare GCE, DNA/GCE, and GR/GCE, respectively. Using DPV in the 0.1   mol   L −1 acetate buffer solution at 0.1   V and with a 300   s accumulation time (pH   =   4.6), the GR-DNA/GCE exhibits a linear current response towards the electrochemical oxidation of NP in the concentration range of 5.0   ×   10 −8 to 4.0   ×   10 −6   mol   L −1 and a detection limit of 1.0   ×   10 −8   mol   L −1 ( S / N   =   3). In addition, this GR-DNA/GCE also indicates high selectivity and reproducibility, and can be successfully used to determine the presence of NP in Asian Clams and natural water samples with comparative sensitivity to high-performance liquid chromatography, and with recoveries ranging from 95% to 103%, showing its practical prospects in the determination of NP in real samples.

本研究中使用的阿拉丁产品

67 款产品在本文中被引用