摘要
The contamination of apple juice by Alicyclobacillus acidoterrestris ( A. acidoterrestris ) can cause significant economic losses. Therefore, developing a rapid and sensitive method for detecting A. acidoterrestris is necessary. To address this issue, this study prepared magnetosome–monoclonal antibodies immunomagnetic microspheres (IMMs) as capture probes to enrich A. acidoterrestris (IMMs-Aa) and monoclonal antibodies-quantum dots (mAb-CdTeQDs) as detection probes for detecting A. acidoterrestris . The obtained IMMs-Aa-mAb-CdTeQDs “sandwich” structure was used to detect A. acidoterrestris based on the fluorescence intensity. The strategy presented a good linear correlation (y = 1048× + 1891, R 2 = 0.995) between the fluorescence intensity and the concentration of A. acidoterrestris (10 1 –10 5 CFU/mL) with a low detection limit of 25.4 CFU/mL within 50 min. The recovery rate of this strategy in spiked apple juice ranged from 88.16 % to 107.03 %. Thus, this study established an efficient and highly sensitive magnetic capture-enrichment-separation-detection method for A. acidoterrestris .
危险品化学品经营许可证(带存储)