摘要
Hydroquinone is an organic pollutant that poses significant risks to the environment and human health, rapid and effective monitoring is essential. In this work, a simple and efficient electrochemical sensor based on poly(3,4-ethylenedioxythiophene) coated onto a bimetallic metal-organic framework (ZnCo-ZIF-67) was constructed by using an in-situ polymerization strategy at room temperature. The electrochemical sensor demonstrates excellent performance with a broad linear range (2–212 μM, 212–662 μM), high sensitivity (0.51 μA·μM −1 ·cm −2 ), and a low limit of detection of 0.468 μM. The sensor exhibits excellent selectivity, repeatability, reproducibility, and anti-interference performance. Moreover, it effectively detects hydroquinone in both tap water and industrial wastewater, achieving recoveries ranging from 97.30 % to 102.83 %, with relative standard deviations (RSD) below 3.80 %. These results highlight the significant potential of the sensor for monitoring hydroquinone in environmental water systems.
危险品化学品经营许可证(带存储)