已核实 DOI PubMed 相关产品: 73

Ratio Fluorescence Sensor Based on Bimetal MOFs for the Detection of Hg2+and H2O2

Journal 2025 · IF 3.1 · 发表于 2025 年 3 月 18 日
作者: Han Bo-Ming,Zhang Hao-Rui,Gao Wen-Jie,He Xi-Wen,Li Wen-You,Zhang Yu-Kui
阅读全文 在 PubMed 查看

摘要

In this work, a dual-emission material based on lanthanide metals was synthesized and used as a ratio fluorescence sensor to respond to Hg 2+ and H 2 O 2 , respectively. Tb-BDC-NH 2 as a bimetal MOFs had double ligands and exhibited double fluorescence emission peaks at 550 nm and 450 nm. The two emission peaks of Tb-BDC-NH 2 can be quenched by Hg 2+ and H 2 O 2 respectively, forming a built-in calibration signal for ratio fluorescence detection. Based on the different detection conditions of the Hg 2+ and H 2 O 2 , the simultaneous detection of the two detection substances can be achieved with simple operation. This detection system had good stability and anti-interference ability. Under optimal conditions, the detection limit for Hg 2+ detection was 0.2 µM. Meanwhile, for the detection of H 2 O 2 , the detection limit was 11 µM and large linear ranges were obtained. Through actual sample testing, it had been proven that the ratio fluorescence sensor based on Tb-BDC-NH 2 had good application prospects. And the work also provided a new idea for double substances detection.

本研究中使用的阿拉丁产品

73 款产品在本文中被引用