已核实 DOI PubMed 相关产品: 41

Recognition and detection of histamine in foods using aptamer modified fluorescence polymer dots sensors

Journal 2024 · IF 4.3 · 发表于 2024 年 5 月 11 日
作者: Gan Wu,Zhaoyang Ding,Xilin Dou,Ze Chen,Jing Xie
阅读全文 在 PubMed 查看

摘要

Histamine has been known as a momentous cause of biogenic amine poisoning. Therefore, the content of histamine in foods is strictly required to be controlled within a certain range. Here, an aptamer fluorescent sensor was developed for detection of histamine. Poly [(9, 9-di-n-octylfluorenyl-2, 7-diyl)-alt-(benzo [2,1,3] thiadia-zol-4, 8-diyl)] (PF8BT) and the styrene maleic anhydride copolymer (PSMA) were used for the preparation of PF8BT-Polymer dots (PF8BT-Pdots). PF8BT-Pdots and the cyanine3-phosphoramidite (Cy3) were linked through aptamer to achieve the ratiometric detection for histamine. PF8BT-Pdots were partly quenched by Cy3 due to the fluorescence resonance energy transfer (FRET), when the histamine molecule was recognized by aptamer on the surface of PF8BT-Pdots. A linear range (3–21 μmol/L) was obtained for histamine detection with a low limit of detection (LOD = 0.38 μmol/L). PF8BT aptamer Pdots (PF8BT-A) were used to detect histamine in simply treated aquaculture water and tuna. The cell imaging of HeLa cells presented a good biosecurity and outstanding fluorescent imaging capability of PF8BT-A. The aptamer fluorescent sensors provided a new platform for rapid and accurate detection of histamine in aquatic products and had great potential for the application in food safety and quality control.

本研究中使用的阿拉丁产品

41 款产品在本文中被引用