Electrochemical detection of tetracycline by zinc oxide modified with molecularly-imprinted polymers

Journal 2025 · IF 2.6 · 发表于 2025 年 4 月 1 日
作者: Yiwei Sun,Yuting Luo,Haoxiang Wang,Yuyang He,Ruoyu Wang,Mengqi Lu,Dongpo Xu
阅读全文 在 PubMed 查看

摘要

An efficient electrochemical molecularly imprinted sensor for the detection of tetracycline (TC) was prepared using ZnO/MIP. ZnO nanomaterials with large surface area improved the electrochemical detection performance and also increased the binding sites of the TC molecularly imprinted polymeric membrane. The TC molecularly imprinted polymeric membrane with pyrrole as the functional monomer specifically binds to TC and thus detects TC in the sample. In this study, the electrochemical performance of ZnO/MIP was evaluated by cyclic voltammetry (CV) and differential pulse voltammetry (DPV). Under the optimal conditions, ZnO/MIP showed a wide detection range. The detection range was 0.1–100 nM, and the detection limit was 0.02 nM with R2 reaching 0.9974. ZnO/MIP has good selectivity, stability, and reproducibility. The recovery of tetracycline in milk was 97–112%.