已核实 DOI PubMed 相关产品: 15

Magnetic Particle-Based Automated Chemiluminescence Immunoassay for the Determination of Hydrocortisone Residues in Milk

Journal 2025 · IF 5.1 · 14(12): 2105 · 发表于 2025 年 6 月 16 日
作者: Yuan-Yuan Yang,Bao-Zhu Jia,Zhen-Lin Xu,Yi-Xian Liu,Lin Luo
阅读全文 在 PubMed 查看

摘要

Hydrocortisone is a typical glucocorticoid commonly used in livestock production; however, its overuse can result in hormone residues in milk. Long-term consumption of such milk may lead to a series of health issues. Therefore, the timely and rapid detection of hydrocortisone in milk is crucial for protecting human health. In this study, a magnetic particle-based direct chemiluminescence immunoassay (MP-DCLIA) incorporating a streptavidin–biotin signal amplification system was developed for the rapid and high-throughput detection of hydrocortisone in milk. Automated operations reduce human error and enhance the accuracy and repeatability of tests. The assay can be completed in 12 min with a linear detection range of 13.09–261.71 μg/L, a limit of detection (LOD) of 4.94 μg/L, a limit of quantification (LOQ) of 14.84 μg/L, and intra- and inter-batch variations of less than 5%. The method demonstrated stability and exhibited no cross-reactivity with structural analogues. Spiked recoveries of milk samples ranged from 85.85% to 100.30%, with results strongly correlating with those obtained from LC-MS/MS. The MP-DCLIA offers rapidity, high efficiency, stability, and precision, making it a promising tool for practical testing applications.

本研究中使用的阿拉丁产品

15 款产品在本文中被引用