已核实 DOI PubMed 相关产品: 0

Solid-state voltammetry-based electrochemical immunosensor for Escherichia coli using graphene oxide–Ag nanoparticle composites as labels

Journal 2013 · IF 3.969 · 138(12): 3388-3393 · 发表于 2013 年 4 月 11 日
作者: Xiaochun Jiang,Kun Chen,Jing Wang,Kang Shao,Tao Fu,Feng Shao,Donglian Lu,Jiangong Liang,M. Frahat Foda,Heyou Han
阅读全文 在 PubMed 查看

摘要

A new electrochemical immunosensor based on solid-state voltammetry was fabricated for the detection of Escherichia coli (E. coli) by using graphene oxide–Ag nanoparticle composites (P-GO–Ag) as labels. To construct the platform, Au nanoparticles (AuNPs) were first self-assembled on an Au electrode surface through cysteamine and served as an effective matrix for antibody (Ab) attachment. Under a sandwich-type immunoassay format, the analyte and the probe (P-GO–Ag–Ab) were successively captured onto the immunosensor. Finally, the bonded AgNPs were detected through a solid-state redox process in 0.2 M of KCl solution. Combining the advantages of the high-loading capability of graphene oxide with promoted electron-transfer rate of AuNPs, this immunosensor produced a 26.92-fold signal enhancement compared with the unamplified protocol. Under the optimal conditions, the immunosensor exhibited a wide linear dependence on the logarithm of the concentration of E. coli ranging from 50 to 1.0 × 106 cfu mL−1 with a detection limit of 10 cfu mL−1. Moreover, as a practical application, the proposed immunosensor was used to monitor E. coli in lake water with satisfactory results.