A facile bioluminescent protocol was developed to detect the total amount of viable Gram-positive bacteria based on a novel antibiotic-affinity strategy. Vancomycin-functionalized magnetic particles were adopted to isolate Gram-positive bacteria from sample matrix, utilizing the five-point hydrogen bonds binding between vancomycin and D-Alanyl- d -Alanine moieties on the cell wall. Then the bioluminescence signal from the bacterial intracellular adenosine triphosphate was collected to quantify the captured bacteria after cells lysis. In this proof-of-principle work, the developed protocol was applied to detect four Gram-positive bacteria, including Staphylococcus aureus , Micrococcus luteus , Bacillus cereus and Streptococcus mutans . It showed a linear range of 1.0 × 10 2 –1.0 × 10 7 CFU mL −1 and a detection limit of 33 CFU mL −1 for the four model bacteria. The whole assay process could be completed within 70 min. Gram-negative bacteria and dead bacteria all showed negligible interference to the detection of the viable Gram-positive bacteria. The method was successfully applied to quantify the amount of viable Gram-positive bacteria in environmental, food and pharmaceutical samples with acceptable recovery values ranging from 72.0% to 120.0%. The protocol possessed numerous advantages such as high sensitivity, low cost, ideal specificity and short detection time. It could also be extended to Gram-negative bacteria detection by utilizing other antibiotics acting on Gram-negative bacteria.