Solution plasma method direct synthesis of Au/CuO nanoparticles for glucose enzyme-free detection

Journal 2020 · IF 2.22 · 31(15): 12983-12990 · 发表于 2020 年 6 月 30 日
作者: Yang Bingqian,Yu Yawei,Qiao Jingyuan,Yuan Lefan,Hu Xiulan
阅读全文 在 PubMed 查看

摘要

Au/CuO nanoparticles with a size range of 20–40 nm directly synthesized by solution plasma method in water have been successfully applied to the non-enzyme detection of glucose. The electrocatalytic activities of Au/CuO nanoparticles toward glucose were evaluated in an alkaline solution by cyclic voltammetry and real-time current method. Research results demonstrate that the biosensor modified by Au/CuO catalysts has a fast reaction time (< 3 s) and low detection limit (0.22 µM). There are two specific linear ranges of 0.22 µM–1 mM and 3 mM–18 mM, with the sensitivities of 172.45 µA mM −1  cm −2 and 63.66 µA mM −1  cm −2 , respectively. Moreover, it also exhibited remarkable current response, good stability (87% after 50 days), superior reproducibility, and excellent selectivity in interfering species (such as D-fructose, ascorbic acid and uric acid). Therefore, the Au/CuO nanoparticles directly synthesized by solution plasma method can be implemented to the enzyme-free detection of glucose.