已核实 DOI PubMed 相关产品: 0

TiO2 decorated Co3O4 acicular nanotube arrays and its application as a non-enzymatic glucose sensor

Journal 2016 · IF 7.476 · 发表于 2016 年 2 月 3 日
作者: Zhenfei Gao,Liqiang Zhang,Chi Ma,Qidong Zhou,Yushu Tang,Zhiqiang Tu,Wang Yang,Lishan Cui,Yongfeng Li
阅读全文 在 PubMed 查看

摘要

TiO 2 modified Co 3 O 4 acicular nanotube arrays (ANTAs) have been fabricated in this study, showing a good performance in glucose detection. In the experiment, the precursor Co(CO 3 ) 0.5 (OH)·0.11H 2 O acicular nanowire arrays (ANWAs) was first grown on the fluorine doped tin oxide (FTO) substrate by a hydrothermal method . Thereafter, the uniform pink precursor Co(CO 3 ) 0.5 (OH)·0.11H 2 O ANWAs was completely converted to the black Co 3 O 4 ANTAs thin film by alkaline treatment . After the decoration of TiO 2 , the TiO 2 /Co 3 O 4 ANTAs electrode exhibits a much higher current response to glucose compared with the Co 3 O 4 ANTAs. Importantly, this neotype composite structure of Co 3 O 4 enhances the glucose sensing performance by increasing specific surface area, additional reactive sites and synergistic effect , which make the TiO 2 /Co 3 O 4 glucose sensor show a high sensitivity of 2008.82   μA   mM −1   cm −2 , a fast response time (less than 5   s) and a detection limit as low as 0.3396   μM (S/N=3). The TiO 2 /Co 3 O 4 ANTAs modified electrode exhibits a high selectivity for glucose in human serum, against ascorbic acid and uric acid .