已核实 DOI 相关产品: 0

A differential strategy to enhance the anti-interference ability of electrochemical molecularly imprinted polymers sensors for the determination of sulfamerazine and 4-acetamidophenol

Journal 2022 · IF 9.221 · 发表于 2022 年 5 月 2 日
作者: Mengru Zhao,Minghui Sun,Qi Kang,Xuemei Ma,Dazhong Shen
阅读全文 在 PubMed 查看

摘要

Herein, we report a differential strategy to enhance the anti-interference ability of the electrochemical molecularly imprinted polymers (MIP) based sensors for the determination of 4-acetamidophenol (AP) and sulfamerazine (SMR). Polypyrrole MIP membranes for AP or SMR were grown independently on the surface of Ni 2 P/GCE, with the imprinting factors of 6.13 for MIP AP and 5.82 for MIP SMR . At the potentials of 0.42 V and 0.89 V (vs. Ag/AgCl), MIP AP /Ni 2 P/GCE and MIP SMR /Ni 2 P/GCE exhibit sensitive current responses to AP and SMR, respectively. However, the non-specific adsorption of various interferents on the surface of MIP suppresses the selectivity of the MIP sensors. For example, 20 μM ascorbic acid (AA) and sulfamethoxazole (SMZ) were determined falsely as 5.2 μM AP and 4.7 μM SMR, respectively. In the proposed differential strategy using the current differences between MIP AP /Ni 2 P/GCE and MIP SMR /Ni 2 P/GCE as the signal indicators, 20 μM of AA and SMZ are equivalent only to 0.25 μM AP and 0.33 μM SMR, respectively, enhancing significantly the anti-interference ability of MIP sensors. Moreover, the limit of detection for AP and SMR are 0.011 and 0.019 μM, respectively. AP and SMR in actual urine samples were determined with the recoveries from 94% to 105%.