已核实 DOI PubMed 相关产品: 8

Spectro-Temporal Ratiometric Strategy for Thermally Invariant Optical Manometry

Journal 2026 · IF 26.8 · 发表于 2026 年 1 月 22 日
作者: Ke Su,Maja Szymczak,Lefu Mei,Xin Pan,Marcin Runowski,Przemysław Woźny,Qingfeng Guo,Bin Ma,Libing Liao,Zhijian Peng,Lukasz Marciniak
阅读全文 在 PubMed 查看

摘要

Optical manometry provides noncontact pressure sensing but remains vulnerable to temperature-induced drift, where thermal expansion and nonradiative relaxation distort luminescence spectra and kinetics. We develop a spectro-temporal ratiometric approach that combines spectral and time-gated luminescence channels to decouple pressure and temperature responses and realize thermally invariant optical manometry. Using Y 3 In 2 Ga 3 O 12 :Cr 3+ as a rigid-lattice host (D q/B ≈ 2.2), lattice stiffness minimizes thermal sensitivity S R,T , while ratiometric detection stabilizes pressure sensitivity S R,p . The resulting thermal-invariance manometric factor ( TIMF) = S R,p / S R,T reaches ≈7700 K·GPa −1 in the spectral domain and ≈2500 K·GPa −1 in the time-gated domain, with S R,p up to 51%·GPa −1 . These values exceed ruby benchmarks by two orders of magnitude and surpass conventional lifetime analysis by ∼40 times, enabling accurate, self-referenced optical pressure mapping under extreme thermo-mechanical conditions. This work provides luminescent manometry from empirical calibration to a quantitative framework for thermally reliable sensing in coupled fields.

本研究中使用的阿拉丁产品