Hypersensitive detection of single millimeter vascular emboli from adhesive in vivo

Journal 2026 · IF 18.1 · 发表于 2026 年 2 月 10 日
作者: Liu Ruihan,Li Shuo,Gao Xingyu,Zou Quan,Shu Gang,Zhang Cai,Pan Jinbin,Chen Xiaoyuan,Sun Shao-Kai
阅读全文 在 PubMed 查看

摘要

Surgical adhesives are widely used in clinical practice but pose a significant risk of severe vascular embolism complications. Nevertheless, there are currently no non-invasive direct methods for precise detection of detached emboli. Herein, we show a CT-visualized method for hypersensitive detection of single millimeter vascular emboli from adhesive in vivo by simply doping BiOCl into surgical adhesives. As proof of concept, BiOCl-BioGlue with excellent CT imaging capability is fabricated and applied to repair ruptured vessels and liver in male rats. The location, morphology, and degradation process of BiOCl-BioGlue can be dynamically monitored by CT imaging for 42 days, and pulmonary emboli caused by BiOCl-BioGlue, with sizes as small as 1.2 mm, are successfully detected. Additionally, the high K-edge of Bi enables precise detection of pulmonary emboli in spectral CT imaging, unaffected by confounding calcifications. The proposed non-invasive detection strategy for adhesive emboli significantly enhances the biosafety of surgical adhesives.

本研究中使用的阿拉丁产品

49 款产品在本文中被引用