已核实 DOI 相关产品: 56

Portable Quantitative Detection of Tetracycline Antibiotics Using Molecularly Imprinted Fluorescent Test Strips

Journal 2026 · IF 2.9 · 16(15): 7636 · 发表于 2026 年 8 月 1 日
作者: Min Liu,Runting Zhang,Chen Zhao,Keding Yan
阅读全文 在 PubMed 查看

摘要

Featured ApplicationThis work provides a portable fluorescence sensing platform for rapid and quantitative detection of tetracycline antibiotics in food samples. The proposed system integrates molecularly imprinted fluorescent test strips with a miniaturized fluorescence detection device and signal processing algorithms, enabling on-site screening of antibiotic residues in complex matrices such as milk and honey. The developed platform has potential applications in food safety monitoring, rapid quality control, and point-of-care testing.To address the challenges of insufficient selectivity, environmentally induced signal instability, and limited quantitative reliability in the on-site rapid detection of tetracycline antibiotics (TCs) in food samples, this study developed a portable quantitative detection method for oxytetracycline (OTC) based on a molecularly imprinted fluorescent test strip. The proposed platform integrates a molecularly imprinted polymer–quantum dot (MIP–QD) recognition system with digital signal processing strategies. CdTe quantum dot-functionalized OTC-imprinted fluorescent test strips were fabricated to enable specific target recognition and fluorescence response. Digital filtering, characteristic peak identification, virtual baseline correction, and peak area integration were employed to improve the stability and accuracy of fluorescence signal extraction. A quantitative model for OTC determination was established based on the fluorescence intensity ratio between the test line and control line (T/C fluorescence ratio). The developed assay exhibited high selectivity toward OTC, with a limit of detection (LOD) of 0.01 μmol/L and a linear detection range of 0.02–0.24 μmol/L. In spiked milk and honey samples, the recoveries of OTC ranged from 96.1% to 100.9% and from 96.9% to 102.4%, respectively, with relative standard deviations (RSDs) below 5%. By integrating molecular imprinting recognition, quantum dot-based fluorescence signaling, and portable digital signal analysis, the proposed method demonstrated reliable quantitative performance in complex food matrices and provides a feasible approach for the on-site rapid screening of tetracycline antibiotics.

本研究中使用的阿拉丁产品

56 款产品在本文中被引用