已核实 DOI 相关产品: 0

Covalently Bonded Donor and Acceptor Microspheres via Soap-Free Emulsion Polymerization for High-Performance Light-Initiated Chemiluminescent Assay Detection of C-Reactive Protein

Journal 2026 · IF 5.1 · 发表于 2026 年 9 月 11 日
作者: Xue Lin,Xiao Song,Yanan Yin,Xiaobing Ren,Xu Gao,Minghui Wang,Zhao Jin,Mingda Wen
阅读全文 在 PubMed 查看

摘要

1.Functional components were incorporated into polystyrene microspheres under surfactant-free conditions, simultaneously improving their monodispersity, optical stability, and functional reliability. • 2.The developed LICA-based CRP detection method exhibited good analytical performance, with stability bias ranging from -3.5% to 0.6%, relative bias for accuracy ranging from -1.0% to 0.7%, within-batch coefficients of variation ranging from 4.20% to 4.70%, and between-batch relative deviations ranging from -6.46% to 4.45%. • 3.Compared with the conventional Immunoassay Technology (IT) method, the LICA method showed good agreement, with 90% of measurements falling within the limits of agreement. C-reactive protein (CRP) is an important biomarker for diagnosing and therapeutic-monitoring inflammatory and cardiovascular diseases. Although the light-initiated chemiluminescent assay (LICA) enables rapid, highly sensitive homogeneous detection, its widespread applications are constrained by the stringent performance requirements for donor and acceptor microspheres. In this study, covalently integrated donor and acceptor microspheres were fabricated through a soap-free emulsion copolymerization strategy by incorporating 2-vinylthiophene, europium complexes, and a photosensitizer into a polystyrene matrix. Subsequently, oxidized dextran surface modification was introduced into the matrix to enhance biocompatibility and biomolecular conjugation efficiency. Thus obtained microspheres exhibited excellent mono-dispersity, high optical stability, and favorable surface characteristics for homogeneous immunoassays. The developed LICA-based CRP assay demonstrated satisfactory analytical performance, with a relative bias ranging from -1.0% to 0.7% for high-concentration samples and from -1.0% to 0.6% for low-concentration samples. The within-run precision showed a coefficient of variation ranging from 4.20% to 4.70%, with between-batch relative bias ranging from 4.45% to 6.46%, all of which satisfied a predefined acceptance criteria of < 8%. Compared with conventional immunoassay technology, the developed assay yielded a mean bias of -1.47 ng/mL, with 90% of measurements falling within the limits of agreement (-6.15 to 4.18 ng/mL), which demonstrates good consistency between the two assays. The developed microspheres provide a reliable material platform for homogeneous LICA and offer a promising potential for clinical applications of CRP detection. Download: Download high-res image (421KB) Download: Download full-size image