已核实 DOI 相关产品: 0

A chiral silicon-based electrochemical sensor for the detection of L-glutamate

Journal 2026 · IF 5.4 · 193(10): 685 · 发表于 2026 年 9 月 18 日
作者: Qin Ziyao,Jia Menggai,Zhan Yue,Yang Molin,Hu Beibei,Li Zhiwei,Sun Shiguo
阅读全文 在 PubMed 查看

摘要

L -Glutamate ( L -Glu), a major excitatory neurotransmitter in the central nervous system, plays an important role in nitrogen metabolism. In this study, chiral mesoporous imprinted silica nanoparticles (CMISNs) were synthesized via the sol-gel method using L -Glu derivatives as templates. Subsequently, the AuNPs/CMISNs@CMK-3/GCE electrochemical sensing interface was constructed. Benefiting from the chiral mesoporous structure of CMISNs and combined high conductivity of CMK-3 and signal amplification effect of gold nanoparticles (AuNPs), the designed electrochemical sensor enables specific detection of L -Glu. The developed sensor exhibits a wide linear response range for L -Glu (1 nM to 1 mM), with a limit of detection of 0.15 nM and a limit of quantification of 0.52 nM. It also demonstrated remarkable enantioselectivity, achieving a chiral separation factor of 7.7 toward glutamate enantiomers, along with good reproducibility (RSD = 3.2%, n  = 5). The sensor retained excellent stability over 14 days and high selectivity against potential interferents. In contrast to conventional enzyme-based biosensors, chiral recognition is achieved by imprinted mesopores of L -Glu without the involvement of biological enzymes. This work provides a novel bionic sensing platform for the precise detection of L -Glu, which holds significant potential in neuroscience research and clinical diagnosis. Graphical abstract