SENSORS AND ACTUATORS B-CHEMICAL
·
2018
·
IF 5.667
Bin Qiao,Yansong Li,Pan Hu,Yu Sun,Zhaozhao Si,Shiying Lu,Honglin Ren,Zengshan Liu,Ying Zhang,Lei Meng,Yu Zhou
Fluorene is a priority pollutant in water listed by U.S. Environmental Protection Agency. A fluorescent probe using Eu(III)-marked polystyrene nanoparticles (EuNPs) labelled with a monoclonal antibody (MAb) was synthesized and an immunochromatographic assay (ICA) based on the probe (EuNPs-MAb) was developed for rapid and sensitive detection of fluorene in water samples. The concentration of fluorene was inversely proportional to fluorescence intensity values of T-line in the range 0.98–62.50 ng/mL. The limit of detection (LOD) for quantitative detection of fluorene was 0.09 ng/mL. Recoveries of fluorene in various water samples ranged from 81.50% to 103.00% and coefficients of variation (CVs) were below 13%, which were in a good agreement with those of traditional ELISA (R 2 = 0.99). The assay can be performed within 30 min. The integrated ICA strip gave higher sensitivity and reliable reproducibility. It could be a potential method for rapid and sensitive detection of fluorene in water samples.
✓ 已验证
产品关联
DOI
高影响因子
GREEN CHEMISTRY
·
2024
·Vol. 26
·期 6
·3211-3220
·
IF 9.3
Pengfei Li,Yehong Han,Dandan Han,Hongyuan Yan
An innovative solid-phase microextraction (SPME) fiber coating, melamine–formaldehyde resin (MFR), was synthesized with a green cross-linker (paraformaldehyde), and it exhibited high heat resistance (up to 350 °C). Seven polycyclic aromatic hydrocarbons (PAHs) were chosen as analytes, and the results demonstrated the MFR-based SPME fiber's exceptional enrichment capabilities and efficient extraction, with high enrichment factors and significantly improved efficiency compared to the conventional polydimethylsiloxane (PDMS) fibers. The unique superiority of the MFR was attributed to its strong π–π interactions and amino-associated enhancement, as well as its porous structure and rough surface, which provided abundant adsorption sites and facilitated rapid mass transport of analytes. Furthermore, the preparation conditions of the MFR-coated SPME fiber were compared with those of commercially available and reported fibers, emphasizing the advantages of the MFR-coated fiber, such as its simplicity, cost-effectiveness, reproducibility, and eco-friendliness. The MFR-based SPME fiber exhibited significant advantages, including high enrichment factors (ranging from 1906- to 7153-fold) for PAHs and good fiber-to-fiber reproducibility (8.7–14.6%), outperforming commercially available PDMS fibers by a factor of 4.9–82.8-fold. This study also considered important factors affecting the extraction process, such as ionic strength, temperature, and time, and optimized these parameters for the best extraction efficiency. The greenness of the developed method was assessed using the Analytical Eco-Scale, and the results showed that it was green in terms of reagent dosage, energy consumption, and waste. The developed headspace solid phase microextraction–gas chromatography–tandem mass spectrometry (HS-SPME-GC-MS/MS) method based on the MFR coating exhibited excellent precision, accuracy, and repeatability, making it a reliable method for the determination of trace PAHs in environmental water samples.
✓ 已验证
产品关联
DOI
高影响因子
FOOD CHEMISTRY
·
2024
·
IF 8.5
Hua Wang,Lin Hao,Yaxing Guo,Chun Wang,Qiuhua Wu,Zhi Wang
Porous electron-rich organic frameworks have attracted an increased attention in the adsorption and removal of pollutants due to their abundant electron-rich nitrogen atoms, which can effectively interact with positively charged substance. In this study, a porous electron-rich organic framework (Car-POF) and positively charged amino-functionalized magnetic nanoparticles (Fe 3 O 4 -NH 2 ) were used to construct a magnetic electron-rich Fe 3 O 4 -NH 2 @Car-POF for the enrichment of some phenylurea herbicides from water and milk samples prior to high performance liquid chromatographic detection. The adsorption capacity of Fe 3 O 4 -NH 2 @Car-POF for the phenylureas ranged from 14.93 to 28.83 mg g −1 . The LODs were observed in the range of 0.05–0.20 ng mL −1 and 0.5–1.5 ng mL −1 , and LOQs in the range of 0.17–0.66 ng mL −1 and 1.7–5.0 ng mL −1 for water and milk samples with RSD less than 9.0. The adsorption studies with cationic and anionic dyes revealed that Fe 3 O 4 -NH 2 @Car-POF is favorable for the adsorption of positively charged compounds.
✓ 已验证
产品关联
DOI
PubMed
高影响因子
FOOD CHEMISTRY
·
2024
·
IF 8.5
Guijiao Zhao,Chenhuan Wang,Min Kang,Lin Hao,Weihua Liu,Zhi Wang,Xiaodong Shi,Qiuhua Wu
Developing effective methods for highly sensitive detection of phenolic endocrine disruptors (EDCs) is especially urgent. Herein, a magnetic hydroxyl-functional porous organic polymer (M-FH-POP) was facilely synthesized by green diazo-couple reaction using basic fuchsin and hesperetin as monomer for the first time. M-FH-POP delivered superior adsorption performance for phenolic EDCs. The adsorption mechanism was hydrogen bonds, hydrophobic interaction and π-π interplay. With M-FH-POP as adsorbent, a magnetic solid phase extraction method was established for extracting trace phenolic EDCs (bisphenol A, 4- tert -butylphenol, bisphenol F and bisphenol B) in water and fish before ultra-high performance liquid chromatography tandem mass spectrometry analysis. The method displayed low detection limit (S/N = 3) of 0.05–0.15 ng mL −1 for water and 0.08–0.3 ng g −1 for fish. The spiked recoveries were 88.3 %–109.8 % with the relative standard deviations of 2.4 %–6.4 %. The method offers a new strategy for sensitive determination of phenolic EDCs in water and fish samples.
✓ 已验证
产品关联
DOI
PubMed
高影响因子
CHEMICAL ENGINEERING JOURNAL
·
2025
·
IF 13.2
Mohammad Farhadpour,Guimei Liu,Qinglan Zhao,Qihua You,Mingguang Pan,Reza Bagheri,Gholamreza Pircheraghi,Minhua Shao
Developing high-performance anion exchange membranes (AEMs) with balanced properties is crucial for the advancement of AEM fuel cells. However, the current performance and durability of AEMs are not promising due to the lack of balance in their properties, where one property, such as swelling ratio, is often sacrificed for another, such as hydroxide conductivity. Consequently, despite recent progress, achieving a trade-off among the various properties of AEMs remains a substantial challenge. Herein, we address this issue through the optimization of crosslinking degree in ether-free polyfluorene-based AEMs. The results demonstrate that an optimal crosslinking degree significantly improves the swelling ratio (<15.9 %), water uptake (<78.0 %), and mechanical properties (>35 MPa), while simultaneously enhancing hydroxide conductivity (>144.6 mS cm -1 ), owing to improved microphase separated morphology. Moreover, the alkaline and oxidative stability of the prepared membranes surpasses that of most state-of-the-art AEMs and represents one of the best-reported chemical stability results, with over 93 – 95 % remaining hydroxide conductivity, ion exchange capacity, and tensile strength after 1080 h in 3 M NaOH solution at 80 °C. Furthermore, the AEM fuel cell achieves a peak power density of 1.03 W cm −2 and excellent durability with a voltage decay rate of 0.62 mV h −1 , surpassing the performance of commercial PiperION TM AEM under identical testing conditions.
✓ 已验证
产品关联
DOI
高影响因子
ANALYTICA CHIMICA ACTA
·
2024
·
IF 5.7
Min Sun,Jiaqing Feng,Yang Feng,Xubo Xin,Yali Ding,Juanjuan Feng
Background Because of the advantages of good selectivity , high sensitivity, and fast analysis, high performance liquid chromatography (HPLC) has become one of the modern analytical techniques in wide application range, such as biological analysis, environmental detection, pharmaceutical and food inspection, agriculture and other fields. The stationary phase greatly decides the chromatographic separation performance, so the development of novel stationary phase is most important for HPLC. Results Pyridyl conjugated microporous polymers (P-CMP) with one to four layers were modified on the surface of amino silica to obtain a novel core-shell material (SiO2@P-CMP) by the layer-by-layer assembly strategy and Chichibabin reaction . The relationship between the structure of SiO2@P-CMP and chromatographic performance was carefully investigated, and the retention mechanism was revealed. The interactions including π-π stacking, hydrophobic effect and hydrogen bond gradually enhanced with the increase of P-CMP layers on the silica surface. Compared with C18 column, SiO2@P-CMP columns displayed better separation selectivity for polycyclic aromatic hydrocarbons (PAHs). According to the relative retention values ( α ), the separation performance of SiO2@P-CMP columns ( α = 1.144–1.884) for PAH isomers and other analytes was obviously better than that of C18 column ( α = 0.998–1.487). Furthermore, the SiO2@P-CMP column with four layers was selected to separate different types of analytes (eight PAHs, four bisphenols , four estrogens and nine phthalates), and the peak order of analytes was different from that on the C18 column due to the influence of hydrogen-bonding and π-π interactions. The relative standard deviations (n = 10) of retention time and peak area on SiO2@P-CMP column were between 0.28 % and 1.98 %. Significance and novelty Pyridyl conjugated microporous polymer was introduced as the stationary phase for the first time in HPLC. The proposed column displayed better separation characteristics compared to Zorbax SB-C 18 column. It provided a new idea for the separation of small molecules and the development of chromatographic packing or extraction material.
✓ 已验证
产品关联
DOI
PubMed
高影响因子
CHEMOSPHERE
·
2024
·
IF 8.1
Hong-Peng Shi,Ying-Hao Zhao,Mei-Lin Zheng,Cheng-Yan Gong,Lei Yan,Ying Liu,Yong-Ming Luo,Zhi-Pei Liu
The performance of bacterial strains in executing degradative functions under the coexistence of heavy metals/heavy metal-like elements and organic contaminants is understudied. In this study, we isolated a fluorene-degrading bacterium, highly arsenic-resistant, designated as strain 2021, from contaminated soil at the abandoned site of an old coking plant. It was identified as a member of the genus Rhodococcus sp. strain 2021 exhibited efficient fluorene-degrading ability under optimal conditions of 400 mg/L fluorene, 30 °C, pH 7.0, and 250 mg/L trivalent arsenic. It was noted that the addition of arsenic could promote the growth of strain 2021 and improve the degradation of fluorene – a phenomenon that has not been described yet. The results further indicated that strain 2021 can oxidize As 3+ to As 5+ ; here, approximately 13.1% of As 3+ was converted to As 5+ after aerobic cultivation for 8 days at 30 °C. The addition of arsenic could greatly up-regulate the expression of arsR / A / B / C / D and pcaG / H gene clusters involved in arsenic resistance and aromatic hydrocarbon degradation; it also aided in maintaining the continuously high expression of cstA that codes for carbon starvation protein and prmA / B that codes for monooxygenase. These results suggest that strain 2021 holds great potential for the bioremediation of environments contaminated by a combination of arsenic and polycyclic aromatic hydrocarbons. This study provides new insights into the interactions among microbes, as well as inorganic and organic pollutants.
✓ 已验证
产品关联
DOI
PubMed
高影响因子
JOURNAL OF CHROMATOGRAPHY A
·
2024
·
IF 3.8
Yali Yang,Jia Chen,Xiaojing Liang,Bei Liu,Kaijun Quan,Xiuhui Liu,Hongdeng Qiu
In this paper, three imidazole- and C18- bifunctional silica stationary phases (Sil-Im-C18) were prepared by adjusting introduction interval of octadecyltrichlorosilane (ODS) and 3-imidazol-1-ylpropyl(trimethoxy)silane (TMPImS), which can be used for reversed-phase liquid chromatography (RPLC) and ion exchange chromatography (IEC) with adjustable performance. The successful preparation of Sil-Im-C18 were confirmed by the characterizations of elemental analysis, infrared spectroscopy (FTIR) and contact angle (CA). Chromatographic performance of Sil-Im-C18 were evaluated by the separation of Tanaka test mixture, alkylbenzenes, linear PAHs and a set of analytes with different properties (uracil, phenol, 1,2-dinitrobenzene and naphthalene), and compared with commonly used C18 column. It was found that the chromatographic performance of Sil-Im-C18 changed significantly with the difference in bonding amount of imidazole and C18. Sil-Im-C18 demonstrated the excellent separation performance towards polycyclic aromatic hydrocarbons (PAHs), phenylesters, phenylamines , phenols and inorganic anions, and notably, nucleobases and nucleosides can be separated using pure water as mobile phases . The van Deemter plot showed that the column efficiency of Sil-Im-C18-3 was 64,933 plate· m − 1 for naphthalene, indicated that Sil-Im-C18 was reasonably chromatographic columns. The RSD values of retention time were 0.22 %-0.61 % for 10 needles alkylbenzenes injected continuously at 50 °C to investigate thermal stability and repeatability, all the fluctuations of k of naphthalene were less than 2.3 % for Sil-Im-C18-1 during flushing 24 h with the mobile phase at different pH values (pH = 3 and 8), the retention time of alkylbenzenes were almost same for Sil-Im-C18-1 at different time, the RSD values of retention time of alkylbenzenes were 0.45 %-2.28 % for two batches Sil-Im-C18-1, revealing the excellent repeatability, thermal stability, durability and reproducibility of Sil-Im-C18, and implying a commercial prospect.
✓ 已验证
产品关联
DOI
PubMed
高影响因子
SEPARATION AND PURIFICATION TECHNOLOGY
·
2024
·
IF 8.1
Xudong Zhang,Yang Deng,Yanhua Liu,Fan Yang,Yugao Wang,Jun Shen
Carbazole is a highly value-added compound derived from crude anthracene. Deep eutectic solvents (DESs) have been extensively used as promising green solvents for the separation of target compounds from mixture. In this work, 135 acidic DESs, formed by combining 9 quaternary ammonium salts with 15 common acids, were screened based on the conductor-like screening model for real solvents (COSMO-RS) model. The four top-ranked DESs, including tetraethylammonium chloride (TEAC)/2 acetic acid (AA), TEAC/2 propionic acid (PA), tetrapropylammonium chloride (TPAC)/2AA, and TPAC/2PA were identified as suitable extractants for carbazole separation based on their performance index (PI). Among them, TEAC/2AA had the best separation performance for carbazole due to its highest PI value (1448.19). Liquid–liquid extraction experiments were performed, and the results were in good accordance with those predicted by COSMO-RS calculations. Therefore, TEAC/2AA was determined as the most promising DES for the carbazole separation. The extraction conditions of TEAC/2AA were optimized. The extraction efficiency (EE) and selectivity (SE) of carbazole were 97.67 % and 66.64 %, respectively, under the optimal extraction conditions (25 ℃, 5 min of extraction time, DES-oil mass ratio of 1:5, initial carbazole concentration of 5000 ppm). Additionally, the deionized water was employed to regenerate the DES and recovery of carbazole. The recycling performance of promising DES was also investigated. Finally, quantum chemical calculations and Fourier Transform Infrared spectroscopy (FT-IR) analysis were conducted to explore the separation mechanism. The results indicated that the separation of carbazole by DESs were predominantly dominated by hydrogen bonds and van der Waals interaction. This work provided a valuable reference for the selection and design of DES extractants to separate other high value-added components from mixture.
✓ 已验证
产品关联
DOI
高影响因子
SEPARATION AND PURIFICATION TECHNOLOGY
·
2024
·
IF 8.1
Chunyan Liu,Yanjuan Liu,Yuefei Zhang,Wei Chen,Sheng Tang
In this work, zeolitic imidazolate framework-67 (ZIF-67) with excellent stability synthesized at room temperature was used together with amphiphilic polymer hydrogel to synthesize a captivating mixed-mode silica stationary phase for the first time. The amphiphilic polymer hydrogel prepared by weakly basic cationic and acidic anionic monomers that was modified on the surface of ZIF-67@SiO 2 by a simple physical coating method not only improved the separation performance, but also enhanced the applicability of ZIF-67@SiO 2 in chromatographic analysis. Meanwhile, the porous ZIF-67 effectively alleviated the problem that polymer hydrogel was easy to swell. To sum up, the amphiphilic polymer hydrogel and ZIF-67 showed excellent synergistic effect in improving the separation ability and the applicability of stationary phase. The experimental results demonstrated that the ZIF-67/hydrogel@SiO 2 stationary phase could be applied in various chromatographic separation modes, demonstrating superior resolution and separation selectivity for polycyclic aromatic hydrocarbons, steroid hormones, nucleosides, B-vitamins, sulfonamides, benzoic acids and dinitrobenzene isomers. In this study, the synergistic expression of ZIF-67 and polymer hydrogel provided a new idea for the development of silica stationary phase co-modified by metal-organic framework and hydrogel material. Concurrently, the successful preparation of ZIF-67/hydrogel@SiO 2 composite revealed a new possibility for utilizing ZIF-67 as the functional material of stationary phase, expanding the application potential of ZIF-67 in the field of chromatography.
✓ 已验证
产品关联
DOI
高影响因子
JOURNAL OF CHROMATOGRAPHY A
·
2020
·
IF 4.049
Yaxing Guo,Ruiyang Ma,Weihua Liu,Lin Hao,Qiuhua Wu,Zhi Wang
A carbazolic conjugated microporous polymer (designated as CZ-CMP) was successfully synthesized through Scholl reaction of carbazole with 1, 3, 5-triphenylbenzene. The CZ-CMP was characterized by FT-IR spectrum, X-ray diffraction, nitrogen sorption isotherms, and scanning electron microscopy. The characterization results showed that the CZ-CMP had a spherical structure with high surface area and good microporosity. Its adsorption performance was investigated by applying it as an adsorbent for the solid phase extraction (SPE) of phenyl urea herbicides (PUHs) (metoxuron, chlortoluron, isoproturon, monolinuron and buturon) from tea drinks samples prior to high performance liquid chromatographic detection. The CZ-CMP displayed high extraction efficiency for the PUHs, and the primary factors affecting the SPE efficiency including the type and volume of the eluent, sample solution pH, sample loading rate and sample volume were optimized. Under the optimized conditions, a good linear response for the analytes was observed in the range of 0.10–80.0 ng mL −1 with correlation coefficients ( r ) from 0.9937 to 0.9997. The limits of detection were measured to be in the range of 0.02–0.30 ng mL −1 and the limits of quantitation were in the range of 0.06–0.9 ng mL −1 . The developed method was successfully applied for the determination of the five PUHs in four different kinds of drinks with the method recoveries between 83.7% and 118% and the relative standard deviations between 1.0% and 10%. Besides, the application potential of the CZ-CMP was evaluated by using it to extract different types of the organic compounds including some phthalate eaters (PAEs), chlorophenol (CPs), nitroimidazoles and polycyclic aromatic hydrocarbons (PAHs). The results indicated that the CZ-CMP had strong adsorption ability for the compounds with more hydrogen bonding sites and moderate hydrophobicity.
✓ 已验证
产品关联
DOI
PubMed
高影响因子
ANALYTICA CHIMICA ACTA
·
2020
·
IF 5.977
Xiaofei Han,Jia Chen,Zhan Li,Kaijun Quan,Hongdeng Qiu
A magnetic porous carbon (Fe 3 O 4 @PC) was successfully fabricated based on combustion combined with solvothermal method , and then used as magnetic solid-phase extraction absorbent for the determination of four triazole fungicides . The porous carbon was fabricated by imperfect combustion of filter paper loaded with zinc nitrate hexahydrate, which possessed extremely abundant pores, high specific surface area (908.05 m 2 g −1 ) and large pore volume . Due to the introduction of solvothermal method used to prepare Fe 3 O 4 @PC, homogeneously distributed magnetic nanoparticles and high saturation magnetization were obtained. Compared with another magnetic porous carbon (Fe 3 O 4 @C), Fe 3 O 4 @PC obviously enhanced enrichment factors and extraction recoveries. Several key parameters influencing extraction efficiency were optimized. The satisfactory enrichment factors, low limits of detection of the method and good linearities were achieved under the optimal conditions. The relative recoveries ranged from 82.8% to 113.2% in three spiked real samples with relative standard deviations lower than 6.2%. The results indicated the great potential of the novel Fe 3 O 4 @PC as adsorbent for the extraction of triazole fungicides from complex real samples.
✓ 已验证
产品关联
DOI
PubMed
高影响因子