文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

347,358+ SCI 论文 与阿拉丁产品引用相关
2,303,472.95 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

产品列表

视图 列表 网格

显示第181至192个,产品总数228个

设置提升方向
SARS-CoV
MICROCHEMICAL JOURNAL · 2022 · IF 5.304

A novel photoelectrochemical immunosensor based on TiO2@Bi2WO6 hollow microspheres and Ag2S for sensitive detection of SARS-COV-2 nucleocapsid protein

Huiqin Chang,Meng Jiang,Qiying Zhu,Anqi Liu,Yuyin Wu,Canguo Li,Xiangyue Ji,Li Gong,Shanshan Li,Zhiwei Chen,Ling Kong,Lei Han

Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-COV-2) is a cluster of β coronaviruses. The 2019 coronavirus disease (COVID-19) caused by SARS-COV-2 is emerging as a global pandemic. Thus, early diagnosis of SARS-COV-2 is essential to prevent severe outbreaks of the disease. In this experiment, a novel label-free photoelectrochemical (PEC) immunosensor was obtained based on silver sulfide (Ag 2 S) sensitized titanium dioxide@bismuth tungstate (TiO 2 @Bi 2 WO 6 ) nanocomposite for quantitative detection of SARS-COV-2 nucleocapsid protein. The constructed TiO 2 @Bi 2 WO 6 hollow microspheres had large specific surface area and could produce high photocurrent intensity under visible light illumination. Ag 2 S was in-situ grown on the surface of thioglycolic acid (TGA) modified TiO 2 @Bi 2 WO 6 . In particular, TiO 2 @Bi 2 WO 6 and Ag 2 S formed a good energy level match, which could effectively enhance the photocurrent conversion efficiency and strength the photocurrent response. Ascorbic acid (AA) acted as an effective electron donor to effectively eliminate photogenerated holes. Under optimal experimental conditions, the constructed immunosensor presented a supersensitive response to SARS-COV-2 nucleocapsid protein, with a desirable linear relationship ranged from 0.001 to 50 ng/mL for nucleocapsid protein and a lower detection limit of 0.38 pg/mL. The fabricated sensor exhibited a wide linear range, excellent selectivity, specificity and stability, which provided a valuable referential idea for the detection of SARS-COV-2.

✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
NEW JOURNAL OF CHEMISTRY · 2023 ·Vol. 48 ·期 4 ·1502-1509 · IF 3.3

Design and numerical-phase analysis of an SPR system for direct detection of SARS-CoV-2 virus in pharyngeal swab solution

Yansheng Liu,Junpeng Deng,Xiaobo Jia,Jin Zhou,Hongli Li,Xiaohong Wang,Yating Chen,Zhenle Qin,Zhichen Jin,Guofu Wang

Quick and highly sensitive detection of the SARS-CoV-2 virus can efficiently reduce the possibility of viral spreading. In this study, a differential-phase surface plasmon resonance (SPR) biosensor is constructed to directly detect the SARS-CoV-2 virus. The SARS-CoV-2 spike protein antibodies are applied as bioprobes and functionalized on Au film, forming a sensing surface. A numerical analysis of the phase shifts of the SPR interferogram, termed the index of phase shifts (IoPS), is presented, which does not depend on a reference beam or an s-component beam. The IoPS can sensitively reflect small changes in the refractive index (as low as 3.75 × 10−10 RIU) when NaCl solution is used as an analyte. The limit of detection (LOD) of the proposed SPR biosensor in detecting the SARS-CoV-2 S protein is 1 ag mL−1. In comparison with a SARS-CoV-2 negative control (NC) sample collected from healthy people, which has an IoPS of ΔϕNC = 39°, the SPR biosensor shows a very strong response to the SARS-CoV-2 virus collected from infected people with a phase shift of ΔϕIoPS = 566°. To further improve the detection sensitivity, a sandwich structure is designed by applying SARS-CoV-2 spike protein antibody functionalized gold nanoparticles (anti-S@AuNPs). This reduces the LOD for the detection of the SARS-CoV-2 S protein to 0.1 ag mL−1.

✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
MICROCHIMICA ACTA · 2024 ·Vol. 191 ·期 12 ·1-10 · IF 5.3

Au@Pt@Pd nanozymes based lateral flow immunoassay for quantitative detection of SARS-CoV-2 nucleocapsid protein in nasal swab samples

Li Chengcheng,Lu Jinhui,Xiang Chao,Zhang Enhui,Tian Xiaofang,Zhang Ling,Li Tingting,Li Chengyao

Three-metal-core-shell nanoparticles (Au@Pt@PdNPs) providing excellent peroxidase-like activity were applied in lateral flow immunoassay (LFIA), designated as Au@Pt@Pd-LFIA, for detecting the nucleocapsid protein (NP) of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). An Au@Pt@Pd-LFIA was developed for quantitatively testing of SARS-CoV-2 NP with a range 0.12–31.25 ng/mL. The limit of detection (LOD) of Au@Pt@Pd-LFIA strip was 0.06 ng/mL, which was 16-fold or eightfold more sensitive than that of the gold lateral flow immunoassay (Au-LFIA) and the gold flower flow immunoassay (AF-LFIA) strips, respectively. For detection of clinical samples from nasal swabs using test strips, Au@Pt@Pd-LFIA had 84.09% sensitivity, 100% specificity, and 92.55% accuracy. In terms of detection time, the testing of Au@Pt@Pd-LFIA strip was 16 min similar to Au-LFIA (15 min) and AF-LFIA (10 min), but much shorter than ELISA (2 h). In conclusion, Au@Pt@Pd-LFIA is a sensitive, rapid, and simple test for quantitative detection of SARS-CoV-2 NP in nasal swab samples. Graphical Abstract

CAS / MDL: 50-81-7 99-20-7 57-50-1
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
APPLIED SURFACE SCIENCE · 2024 · IF 6.3

An antifouling electrochemical sensor integrating ‘‘3-in-1″ dual-targeted aptamer for the detection of the SARS-CoV-2 spike protein

Jialin Zhao,Ting Wu,Youlin Xiong,Wei Zhang,Zian Pan,Shuangfei Cai,Rong Yang

Electrochemical biosensors have shown promise in bioanalysis and diagnosis. However, they suffer from the accumulation and adhesion of biomolecules in biofluids on sensing surfaces, while the hiring of potential antifouling is limited by the cost and complexity of the construction methods. Here, an economical three-dimensional (3D) conductive antifouling coating was prepared. This coating was composed of bovine serum albumin (BSA) crosslinked glutaraldehyde (GA) and copper-gold nanowires (CuAu NWs) with excellent electrical conductivity. Furthermore, a dual-targeted aptamer (D-Apt), with a “3-in-1″ structure of two specific binding sequences and a DNA linker, was designed to specifically recognize BSA and the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) spike (S) protein, affording low nanomolar binding affinity. Importantly, the introduction of the D-Apt greatly simplified the functionalization procedure on the electrode surface and the immobilization of the biorecognition element. Then, a simple electrochemical biosensor based on the CuAu/BSA/GA and D-Apt was constructed for the detection of S protein. This sensor exhibited merits of cost-effectiveness, sensitivity and practicality for detection of S protein. The work could provide a facile avenue to construct electrochemical biosensors with low-cost antifouling for the accurate diagnosis of epidemic antigenic disease markers.

CAS / MDL: 57-09-0
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
ANALYTICA CHIMICA ACTA · 2024 · IF 5.7

Sensitivity-improved SERS detection of SARS-CoV-2 spike protein by Au NPs/COFs integrated with catalytic-hairpin-assembly amplification technology

Qiuwen Huang,Na Zhou,Jiayi Peng,Xuanjiang Zeng,Lijuan Du,Yan Zhao,Xiaojun Luo

Background The COVID-19 pandemic, caused by the novel coronavirus, has had a profound impact on global health and economies worldwide. This unprecedented crisis has affected individuals, communities, and nations in diverse manners. Developing simple and accurate diagnostic methods is an imperative task for frequent testing to mitigate the spread of the virus. Among these methods, SARS-CoV-2 antigen tests in clinical specimens have emerged as a promising diagnostic method for COVID-19 due to their sensitive and accurate detection of spike (S) protein, which plays a crucial role in viral infection initiation. Results In this work, a dual-signal amplification surface enhanced Raman scattering (SERS)-based S protein biosensor was constructed based on Au NPs/COFs and enzyme-free catalytic hairpin assembly (CHA) amplification method. The approach relies on a released free DNA sequence (T), which is generated from the competition reaction between Aptamer/T and Aptamer/S protein, to trigger a CHA reaction. Due to the high binding affinity and selectivity between the S protein and its aptamer, CHA process was triggered with the maximum SERS tags (H2-conjugated Au@4-mercaptobenzonitrile@Ag) anchored onto Au NPs/COFs substrate surface. This SERS platform could detect the S protein at concentrations with high sensitivity (limit of detection = 3.0 × 10 −16  g/mL), wide detection range (1 × 10 −16 to 1 × 10 −11  g/mL), acceptable reproducibility (relative standard deviation = 7.01 %) and excellent specificity. The biosensor was also employed to detect S protein in artificial human salivas. Significance Thus, this study not only developed a novel Au NPs/COFs substrate exhibiting strong SERS enhancement ability and high reproducibility, but also proposed a promising dual-signal amplification SERS-based diagnostic method for COVID-19, holding immense potential for the detection of a wide range of antigens and infectious diseases in future applications.

✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
SENSORS AND ACTUATORS B-CHEMICAL · 2021 · IF 7.46

Automatic label-free immunoassay with high sensitivity for rapid detection of SARS-CoV-2 nucleocapsid protein based on chemiluminescent magnetic beads

Aihua Lyu,Tengchuan Jin,Shanshan Wang,Xiaoxue Huang,Weihong Zeng,Rui Yang,Hua Cui

Accurate and efficient early diagnosis is crucial for the control of COVID-19 pandemic. However, methods that can balance sensitivity, high throughput, detection speed and automation simultaneously are still scarce. Here, we report an automatic label-free chemiluminescence immunoassay (CLIA) for rapid SARS-CoV-2 nucleocapsid protein (NP) detection with high sensitivity and throughput. N-(4-aminobutyl)-N-ethylisoluminol and Co 2+ dual-functionalized chemiluminescent magnetic beads (dfCL-MB) were first applied to the detection of protein by a novel and simple strategy. Sulphydryl polyethylene glycol was coated on the surface of dfCL-MB so as to assemble dfCL-MB and antibody conjugated gold nanoparticles through Au-S bond. Considering the high-risk application scenarios, the immunosensor was integrated with an automatic chemiluminescence analyzer so that the whole testing procedure could be carried out automatically without manual operation. A linear correlation between CL intensities and the logarithm of NP concentration was obtained in the range of 0.1–10,000 pg/mL with a detection limit of 21 fg/mL. The whole process cost 25 min and the sample compartment can bear 24 samples simultaneously. The spiked human serum samples and serum samples from COVID-19 patients were determined with satisfactory recoveries of 91.1–109.4%, suggesting that the proposed label-free CLIA is of great potential for SARS-CoV-2 NP detection in practice.

✓ 已验证 DOI PubMed 高影响因子
查看原文 查看 PubMed
Frontiers in Cellular and Infection Microbiology · 2021 · IF 5.293

Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) Membrane (M) and Spike (S) Proteins Antagonize Host Type I Interferon Response

Zhang Qi,Chen Zhiqiang,Huang Chenxiao,Sun Jiuyuan,Xue Minfei,Feng Tingting,Pan Wen,Wang Kezhen,Dai Jianfeng

Coronavirus disease 2019 (COVID-19), caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), has spread worldwide and has infected more than 250 million people. A typical feature of COVID-19 is the lack of type I interferon (IFN-I)-mediated antiviral immunity in patients. However, the detailed molecular mechanisms by which SARS-CoV-2 evades the IFN-I-mediated antiviral response remain elusive. Here, we performed a comprehensive screening and identified a set of SARS-CoV-2 proteins that antagonize the IFN-I response. Subsequently, we characterized the mechanisms of two viral proteins antagonize IFN-I production and downstream signaling. SARS-CoV-2 membrane protein binds to importin karyopherin subunit alpha-6 (KPNA6) to inhibit interferon regulatory factor 3(IRF3) nuclear translocation. Further, the spike protein interacts with signal transducer and activator of transcription 1 (STAT1) to block its association with Janus kinase 1 (JAK1). This study increases our understanding of SARS-CoV-2 pathogenesis and suggests novel therapeutic targets for the treatment of COVID-19.

✓ 已验证 DOI PubMed 高影响因子
查看原文 查看 PubMed
MICROCHEMICAL JOURNAL · 2023 · IF 4.8

An electrochemiluminescence sensing platform combining entropy-driven amplification strategy and inverted DNA tetrahedral nanomachines for detecting SARS-CoV-2 specific gene

Jiaying Wang,Bin Li,Bo Yao,Yi Zhao,Kai Zhang

In this work, we propose a Ti 3 C 2 T x -based electrochemiluminescence (ECL) sensing platform, combined with a programmable entropy-driven cycling strategy and inverted DNA tetrahedral nanomachines to detect the SARS-CoV-2 RdRp gene. The use of Ti 3 C 2 T x in the ECL sensing platform provides unique advantages that improve the assay's sensitivity. Firstly, the SARS-CoV-2 RdRp gene triggers an entropy-driven cyclic amplification reaction to obtain a large number of Output strands. Subsequently, the Output strand reacts with an inverted DNA tetrahedral swing arm strand to start the self-driven process. Finally, the ferrocene (Fc)-labeled hairpin DNA strand of the inverted DNA tetrahedron is severed to achieve the signal change. Under optimal conditions, the ECL platform integrated with entropy-driven cycle amplification reaction and inverted DNA tetrahedral nanomachines obtained a wide range of 100 aM to 10 nM and a limit of detection (LOD) of 48.3 aM for the SARS-CoV-2 RdRp gene. Moreover, the recovery rates of 97% to 103.3% and 98.34% to 103% were obtained in real environments and human pharyngeal swabs, respectively. This ECL sensing platform, which combines an entropy-driven cycle amplification reaction and inverted DNA tetrahedral nanomachines, opens up new opportunities for the detection of other substances.

✓ 已验证 DOI 高影响因子
查看原文 查看 PubMed
BIOELECTROCHEMISTRY · 2023 · IF 5

Molecularly imprinted miniature electrochemical biosensor for SARS-CoV-2 spike protein based on Au nanoparticles and reduced graphene oxide modified acupuncture needle

Xu Yang,Zheng-Zhi Yin,Guojun Zheng,Min Zhou,Hongyu Zhang,Junyao Li,Wenrong Cai,Yong Kong

Accurate detection of SARS-CoV-2 spike (SARS-CoV-2-S) protein is of clinical significance for early diagnosis and timely treatment of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Herein, a surface molecularly imprinted miniature biosensor was fabricated. Au nanoparticles (AuNPs), reduced graphene oxide (rGO), poly(methylene blue)/poly(ionic liquids) and poly(ionic liquids) were successively electrodeposited onto the pinpoint of an acupuncture needle (AN). The molecularly imprinted miniature biosensor was obtained after the template of SARS-CoV-2-S protein was removed, which could be used for sensitive detection of SARS-CoV-2-S protein. The linear range and limit of detection (LOD) were 0.1 ∼ 1000 ng mL −1 and 38 pg mL −1 , respectively, which were superior to other molecularly imprinted biosensors previously reported. The developed miniature biosensor also exhibited high specificity and stability. The reliability of the biosensor was evaluated by the detection of SARS-CoV-2-S protein in clinical serum samples.

✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
MATERIALS & DESIGN · 2022 · IF 9.417

Rapid and ultrasensitive detection of SARS-CoV-2 spike protein based on upconversion luminescence biosensor for COVID-19 point-of-care diagnostics

Lihua Li,Menglin Song,Xinyue Lao,Sin-Yi Pang,Yuan Liu,Man-Chung Wong,Yingjin Ma,Mo Yang,Jianhua Hao

Here, we firstly introduce a detection system consisting of upconversion nanoparticles (UCNPs) and Au nanorods (AuNRs) for an ultrasensitive, rapid, quantitative and on-site detection of SARS-CoV-2 spike (S) protein based on Förster resonance energy transfer (FRET) effect. Briefly, the UCNPs capture the S protein of lysed SARS-CoV-2 in the swabs and subsequently they are bound with the anti-S antibodies modified AuNRs, resulting in significant nonradiative transitions from UCNPs (donors) to AuNRs (acceptors) at 480 nm and 800 nm, respectively. Notably, the specific recognition and quantitation of S protein can be realized in minutes at 800 nm because of the low autofluorescence and high Yb-Tm energy transfer in upconversion process. Inspiringly, the limit of detection (LOD) of the S protein can reach down to 1.06 fg mL −1 , while the recognition of nucleocapsid protein is also comparable with a commercial test kit in a shorter time (only 5 min). The established strategy is technically superior to those reported point-of-care biosensors in terms of detection time, cost, and sensitivity, which paves a new avenue for future on-site rapid viral screening and point-of-care diagnostics.

✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
International Journal of Nanomedicine · 2022 · IF 7.033

Exosomal Vaccine Loading T Cell Epitope Peptides of SARS-CoV-2 Induces Robust CD8+ T Cell Response in HLA-A Transgenic Mice

An-Ran Shen,Xiao-Xiao Jin,Tao-Tao Tang,Yan Ding,Xiao-Tao Liu,Xin Zhong,Yan-Dan Wu,Xue-Lian Han,Guang-Yu Zhao,Chuan-Lai Shen,Lin-Li Lv,Bi-Cheng Liu

Purpose Current vaccines for the SARS-CoV-2 virus mainly induce neutralizing antibodies but overlook the T cell responses. This study aims to generate an exosomal vaccine carrying T cell epitope peptides of SARS-CoV-2 for the induction of CD8 + T cell response. Methods Thirty-one peptides presented by HLA-A0201 molecule were conjugated to the DMPE-PEG-NHS molecules, and mixed with DSPE-PEG to form the peptide-PEG-lipid micelles, then fused with exosomes to generate the exosomal vaccine, followed by purification using size-exclusion chromatography and validation by Western blotting, liquid nuclear magnetic resonance (NMR) test and transmission electron microscopy. Furthermore, the exosomal vaccine was mixed with Poly (I:C) adjuvant and subcutaneously administered for three times into the hybrid mice of HLA-A0201/DR1 transgenic mice with wild-type mice. Then, the epitope-specific T cell responses were detected by ex vivo ELISPOT assay and intracellular cytokine staining. Results The exosomal vaccine was purified from the Peak 2 fraction of FPLC and injected into the hybrid mice for three times. The IFN-γ spot forming units and the frequencies of IFN-γ + /CD8 + T cells were 10–82-fold and 13–65-fold, respectively, higher in the exosomal vaccine group compared to the Poly (I:C) control group, without visible organ toxicity. In comparison with the peptides cocktail vaccine generated in our recent work, the exosomal vaccine induced significantly stronger T cell response. Conclusion Exosomal vaccine loading T cell epitope peptides of SARS-CoV-2 virus was initially generated without pre-modification for both peptides and exosomes, and elicited robust CD8 + T cell response in HLA-A transgenic mice.

CAS / MDL: 121-44-8
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
BIOELECTROCHEMISTRY · 2023 · IF 5

Facile construction of nanocubic Mn3[Fe(CN)6]2@Pt based electrochemical DNA sensors for ultrafast precise determination of SARS-CoV-2

Mengjiao Zhu,Yu Liu,Meiyue Wang,Tao Liu,Zhenyu Chu,Wanqin Jin

Owing to the high mortality and strong infection ability of COVID-19, the early rapid diagnosis is essential to reduce the risk of severe symptoms and the loss of lung function. In clinic, the commonly used detection methods, including the computed tomography (CT) and reverse transcription-polymerase chain reaction (RT-PCR), are often time-consuming with bulky instruments, which normally require more than one hour to report the results. To shorten the analytical period for testing the COVID-19 virus (SARS-CoV-2), we proposed an ultrafast and ultrasensitive DNA sensors to achieve an accurate determination of the DNA sequence by the RNA reverse transcription (rtDNA) of the SARS-CoV-2. A nanocubic architecture of the MnFe@Pt crystals was constructed to integrate both electrocatalysis and conductivity to greatly improve the biosensing performance. After the immobilization of a specific capture and report DNA on above nanocomposite, the rtDNA can be rapidly caught to the DNA sensor to form a double-helix structure, thus generating the current signal change. Within only 10 min, the as-prepared DNA sensors exhibited ultralow detection limit (1 × 10 −20 M) and wide linear detection range, together with an outstanding selectivity among various interfering substances.

✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。