Dongsheng Zhao,Wenqian Li,Rongmei Wen,Nana Lei,Wencui Li,Xin Liu,Xiutang Zhang,Liming Fan
With the introduction of Eu3+ ions as the secondary fluorescent signal reporter and sensing active sites, a dual-emission ratiometric sensor of Eu3+@NiMOF (Eu3+ functional NiMOF) for hippuric acid (HA) detection in urine and serum was fabricated via the postsynthetic encapsulating strategy. Based on the two emission signals at 441 nm (turn-on) and 628 nm (turn-off), the produced Eu3+@NiMOF ratiometric sensor provided enhanced sensitivity, higher selectivity, and 9.7 times lower limits of detection (LOD) for the detection of HA (2.38 μM, 0.42 μg·mL–1) than that of the pristine NiMOF. Considering the high sensitivity and visualization results, further exploration of intelligent applications in the HA sensing process was carried out by constructing a tandem combinational logic gate to improve the practicability and convenience with the help of a smartphone. This work provides a promising approach for developing MOF-based ratiometric sensors to detect biomarkers.
Immobilized metal affinity chromatography has drawn great attention as a widespread separation and purification approach. In this work, ruthenium was firstly introduced into the preparation of immobilized metal affinity chromatography considering its affinity to N,O-donor ligands. A β-cyclodextrin-functionalized poly(glycidyl methacrylate-ethylene dimethacrylate) monolith was designed and employed as the supporting material in immobilized metal affinity chromatography. Thiosemicarbazide was introduced into the synthesis process, which not only acted as a bridge between β-cyclodextrin and glycidyl methacrylate, but also chelated with ruthenium because of its mixed hard-soft donor characteristics. The developed monolithic ruthenium(III)-immobilized metal affinity chromatography column was utilized for the adsorption and separation of hippuric acid, a biological indicator of toluene exposure. To achieve high extraction capacity, the parameters affecting the extraction efficiency were investigated with an orthogonal experiment design, L9 (3 4 ). Under the optimized conditions, the enrichment factor of hippuric acid was 16.7-fold. The method reproducibility was investigated in terms of intra- and interday precisions with relative standard deviations lower than 8.7 and 9.5%, respectively. In addition, ruthenium(III)-immobilized metal affinity chromatography material could be used for up to 80 extractions without an apparent change in extraction recovery.