文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

显示第13至24个,产品总数25个

设置提升方向
LFIA
Analytical Methods · 2022 ·Vol. 14 ·期 24 ·2423-2430 · IF 3.532

A novel lateral flow immunoassay strip based on a label-free magnetic Fe3O4@UiO-66-NH2 nanocomposite for rapid detection of Listeria monocytogenes

Juan Du,Kai Liu,Jialei Liu,Dianbo Zhao,Yanhong Bai

Listeria monocytogenes (L. monocytogenes) is one of the most lethal pathogenic bacteria. Although the traditional microbial culture method has high sensitivity and selectivity for the diagnosis of L. monocytogenes, it is time-consuming and not suitable for on-site detection. A rapid, convenient and visualized on-site detection method is particularly needed. In this work, Fe3O4@UiO-66-NH2 was prepared for both magnetic separation and lateral flow immunoassay (LFIA) for the detection of L. monocytogenes by taking advantage of the easy separation of the magnetic core Fe3O4 and the high surface area of the outer layer UiO-66-NH2. Fe3O4@UiO-66-NH2 with a high surface area and good water-dispersibility and optical properties was synthesized by a simple hydrothermal process. It could directly adsorb on the surface of target bacteria and form Fe3O4@UiO-66-NH2-bacteria conjugates, without the labeling of an antibody. After magnetic separation and concentration, the Fe3O4@UiO-66-NH2-bacteria conjugates were detected by the antibody on the test line of the LFIA strip, resulting in a visible orange band. The capture efficiency and LFIA detection of Fe3O4@UiO-66-NH2 were optimized in this study. Under the optimal conditions, a good linear correlation between the test line intensity and the concentration of L. monocytogenes was obtained in the range of 105–108 CFU mL−1, and the limit of detection was 2.2 × 106 CFU mL−1 by the naked eye. The Fe3O4@UiO-66-NH2-based LFIA strip showed strong specificity for L. monocytogenes, and the detection took 45 min without culture enrichment. Therefore, the proposed Fe3O4@UiO-66-NH2-based strip showed the advantages of simple synthesis, being label-free, low cost, good selectivity and convenience.

CAS / MDL: 10026-11-6 6132-04-3
研究领域: 生物技术 · 分析化学 · 食品安全
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
MOLECULES · 2022 ·Vol. 27 ·期 13 ·4019 · IF 4.927

Ultrasensitive and Specific Detection of Anticancer Drug 5-Fluorouracil in Blood Samples by a Surface-Enhanced Raman Scattering (SERS)-Based Lateral Flow Immunochromatographic Assay

Hanwen Liu,Ying Liu,Ting Zhou,Penghui Zhou,Jianguo Li,Anping Deng

5-Fluorouracil (5-FU) is an effective anticancer drug widely used in the world. To improve therapy efficiency and reduce side effects, it is very important to frequently detect the concentration of 5-FU in blood samples of patients. In this work, a new type of lateral flow immunochromatographic assay (LFIA) based on surface-enhanced Raman scattering (SERS) for ultrasensitive and specific detection of 5-FU in blood samples was developed. Au@Ag/Au nanoparticles (NPs) employing Au particles as the core and Ag/Au alloy as the shell were synthesized, characterized and used as the substrate in SERS-LFIA due to their high SERS enhancement and biocompatibility. The immunoprobe was made in the form of AuMBA@Ag/Au-Ab in which mercaptobenzoic acid (MBA, a common Raman active reporter) was embedded in the core–shell layer and the monoclonal antibody (mAb) against 5-FU was immobilized on the surface. The performance of SERS-LFIA was similar to that in colloidal gold based-LFIA, and the entire assay time was within 20 min. According to the color intensity on the testing (T) lines of LFIA strips visualized by eyes, the contents of 5-FU in the samples could be qualitatively or semi-quantitatively identified. Furthermore, by measuring the characteristic Raman intensities of MBA on T lines, quantitative detection of 5-FU in the samples were achieved. The IC50and limit of detection (LOD) of the LFIA for 5-FU were found to be 20.9 pg mL−1and 4.4 pg mL−1, respectively. There was no cross-reactivity (CR) of the LFIA with nine relative compounds, and the CR with cytosine, tegafur and carmofur were less than 4.5%. The recoveries of 5-FU from spiked blood samples were in the range of 78.6~86.4% with the relative standard deviation (RSD) of 2.69~4.42%. Five blood samples containing 5-FU collected from the Cancer Hospital were measured by SERS-LFIA, and the results were confirmed by LC-MS/MS. It was proven that the proposed method was able to simply and rapidly detect 5-FU in blood samples with high sensitivity, specificity, accuracy and precision.Keywords:surface-enhanced Raman scattering (SERS);lateral flow immunochromatographic assay (LFIA);5-fluorouracil (5-FU);anticancer drug;blood samples

研究领域: 分析化学 · 医学诊断 · 药学
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
Small Methods · 2024 · IF 10.7

Flexible Scaffold Modulation of Spatial Structure and Function of Hierarchically Porous Nanoparticle@ZIF-8 Composites to Enhance Field Deployable Disease Diagnostics

Chunyang Li,Yujian Li,Shaoyan Wu,Gui Li,Juan Li,Yan Zhao,Huan Cai,Jia Shu,Mingxuan Song,Qing Fu,Jianbo Yuan,Xin Gao,Zhujun Ai,Xiaosong Li,Rui Chen,Zhong Zuo

Catalytic nanoparticle@metal-organic framework (MOF) composites have attracted significant interest in point-of-care testing (POCT) owing to their prominent catalytic activity. However, the trade-off between high loading efficiency and high catalytic activity remains challenging because high concentrations of nanoparticles tend to cause the misjoining and collapse of the MOFs. Herein, a facile strategy is reported to encapsulate high concentrations of platinum (Pt) nanoparticles into zeolitic imidazolate framework-8 (ZIF-8) using polydopamine (PDA) as a support for Pt@ZIF-8 and as a flexible scaffold for further immobilization of Pt nanoparticles. The resulting composite (Pt@ZIF-8@PDA@Pt) exhibits ultrahigh Pt nanoparticle loading efficiency, exceptional catalytic activity, stability, and a bright colorimetric signal. Following integration with lateral flow immunoassay (LFIA), the detection limits for pre- and post-catalysis detection of B-type natriuretic peptide (NT-proBNP) are 0.18 and 0.015 ng mL −1 , respectively, representing a 6-fold and 70-fold improvement compared to gold nanoparticle-based LFIA. Moreover, Pt@ZIF-8@PDA@Pt-based LFIA achieves 100% diagnostic sensitivity for NT-proBNP in a cohort of 184 clinical samples.

研究领域: 纳米技术 · 催化 · 诊断 · 材料科学 · 生物医学工程
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
TALANTA · 2024 · IF 5.6

A colorimetric and SERS-based LFIA for sensitive and simultaneous detection of three stroke biomarkers: An ultra-fast and sensitive point-of-care testing platform

Yutong Wang,Qianchun Zhang,Mengping Huang,Ganggang Ai,Xiaofeng Liu,Yuqi Zhang,Ran Li,Jie Wu

Stroke ranks as the second leading cause of disability and mortality globally. Biomarker detection represents a promising avenue for predicting disease severity and prognosis. The expression levels of metalloproteinase-9 (MMP-9), neuron-specific enolase (NSE), and N-terminal pro-brain natriuretic peptide (NT-pro BNP) in blood correlate with stroke severity. Hence, monitoring these biomarkers is crucial for stroke diagnosis and management. Point-of-care testing (POCT) offers on-site diagnostic capabilities, with lateral flow immunoassay (LFIA) being the most widely used method currently. However, traditional LFIA sensitivity requires enhancement. This study introduces an ultra-sensitive surface-enhanced Raman scattering-based lateral flow immunoassay (SERS-based LFIA) strip for simultaneous detection of the three stroke biomarkers using SERS immune tags. Bimetallic core-shell structured SERS immune tags leverage the advantages of two metals, ensuring stability and enhancing Raman signals through plasmon resonance. This development of a POCT based on SERS-based LFIA strips offers rapid, sensitive, and multiplex detection of stroke biomarkers. The limits of detection (LODs) for MMP-9, NSE, and NT-pro BNP were 0.00020 ng mL −1 , 0.00016 ng mL −1 , and 0.00012 ng mL −1 , respectively. Furthermore, enzyme-linked immunosorbent assay (ELISA) validated the accuracy of SERS-based LFIA. Clinical sample analysis demonstrated consistency between outcomes obtained by SERS-based LFIA and ELISA. Thus, SERS-based LFIA presents a novel POCT approach for stroke diagnosis.

研究领域: 医学诊断 · 生物传感技术
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
JOURNAL OF COLLOID AND INTERFACE SCIENCE · 2022 · IF 9.965

Versatile Au@Ru nanocomposites for the rapid detection of Salmonella typhimurium and photothermal sterilization

Li Ji,Leheng Zhang,Huiyi Yang,Shan Liang,Junkang Pan,Yikui Zou,Shijia Li,Qinglan Li,Suqing Zhao

In view of the current public health hazards of food-borne pathogens, it is urgent to develop a rapid detection method with high sensitivity, good specificity and operational convenience, as well as to determine an effective sterilization strategy. Herein, versatile gold-ruthenium nanocomposites modified with antibody ( [email protected] Ncs) have been constructed for the sensitive detection of Salmonella typhimurium (S. typhimurium) via the lateral flow immunochromatographic assay (LFIA). [email protected] Ncs based LFIA exhibited a wide detection range from 2.9 × 10 6 CFU/mL to 2.9 × 10 11 CFU/mL with the limit of detection of 9.8 × 10 4 CFU/mL for S. typhimurium, and displayed excellent specificity. In addition, [email protected] Ncs irradiated with 808 nm (500 mW/cm 2 ) near-infrared light (NIR) had a significant antibacterial effect within only 5 min, attributed to its high photothermal conversion efficiency of 54.14%. Therefore, both sensitive detection of S. typhimurium and effective NIR-triggered photothermal sterilization were achieved by using versatile [email protected] Ncs, showing great prospects in the field of pathogen detection and treatment.

研究领域: 纳米技术 · 食品安全 · 细菌学 · 生物医学工程
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
Analytical Methods · 2022 ·Vol. 14 ·期 26 ·2586-2595 · IF 3.532

Using a quantum dot bead-based lateral flow immunoassay to broadly detect the adulteration of PDE-5 inhibitors in functional foods

Mingshu Song,Qin Wu,Beibei Liu,Pan Li,Lan Jiang,Yulong Wang,Sa Dong,Yonghua Xiong,Bruce D. Hammock,Cunzheng Zhang

In this study, a designed hapten possessing the classic structure of PDE-5 inhibitors was synthesized. A monoclonal antibody (mAb) with broad recognition for six PDE-5 inhibitors was further produced. For the determination of lodenafil, methisosildenafil, mirodenafil, udenafil and tadalafil, the limit of detection (LOD) and IC50 ranged from 1.01 to 26.91 ng mL−1 and 12.75 to 278 ng mL−1, respectively. Thereafter, a quantum dot bead-based lateral flow immunoassay (QB-LFIA) was developed, which improved the LOD and IC50 to 0.32–6.52 ng mL−1 and 7.45–133.8 ng mL−1, respectively. Method validation was conducted using honey and capsule samples spiked with PDE-5 inhibitors, and the recoveries of the intra- and inter-assays ranged from 81.01% to 108.16%, with coefficients of variation below 12.71%. In addition, the validity and the consistency have been confirmed with a comparison between QB-LFIA and HPLC-MS/MS (R2 = 0.9957). Furthermore, the developed QB-LFIA was employed for the inspection of real products, and several samples were found to be adulterated with lodenafil and methisosildenafil.

研究领域: 分析化学 · 食品科学 · 药物分析 · 免疫学
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
TALANTA · 2024 · IF 5.6

A “Four-in-One” Immunochromatographic Strip for Multi-Readout Detection of Diazepam in Lake Water and Fish via Nanozyme-Mediated Colorimetric, Catalytic, and Photothermal Activities

Fuyuan Zhang,Jing Wang,Weihua Liu,Qingge Shi,Hangrui Liu,Yaxin Sang,Xianghong Wang

The presence of psychotropic drugs (PDs) in aquatic ecosystems represents an increasing environmental problem, posing a serious threat to human health and aquatic organisms. Lateral flow immunoassays (LFIA) have been widely used in the detection of PD contaminants. However, maintaining signaling tag reporting activity and achieving LFIA's multi-readout capability remain significant challenges to meeting a range of detection scenarios. Here, a rapid multifunctional LFIA has been developed for detecting diazepam (DAP), an emerging environmental and food safety PD contaminant, in lake water and fish samples. Copper hexacyanoferrate nanoparticles doped with Au and Pt (AuPt@Cu-HCF) were designed and manufactured as a multi-signal reporter with exceptional photothermal conversion efficiency and peroxidase-like enzymatic activity. This study integrates the colorimetric, photothermal, catalytic colorimetric, and catalytic photothermal effects of the AuPt@Cu-HCF nanozyme to form a “four-in-one” multi-readout LFIA. The multifunctional detection approach achieved four different detection signal outputs for DAP, with detection limits of 0.82 ng/mL, 12.82 pg/mL, 12.26 pg/mL, and 4.43 pg/mL for the basic colorimetric, photothermal, catalytic colorimetric, and colorimetric photothermal readout modes, respectively. This quadruplex-functional LFIA offers four different options with varying sensitivities and detection ranges, suitable for various application scenarios. It also allows multiple verifications for a single sample, enhancing detection accuracy.

CAS / MDL: 7758-99-8
研究领域: 环境科学 · 分析化学 · 纳米技术 · 食品安全 · 生物技术
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
Small · 2021 ·Vol. 17 ·期 25 ·2100862 · IF 13.281

Compact Magneto-Fluorescent Colloids by Hierarchical Assembly of Dual-Components in Radial Channels for Sensitive Point-of-Care Immunoassay

Liang Huang,Yuxing Zhang,Tao Liao,Kui Xu,Chenxing Jiang,Dinglv Zhuo,Yang Wang,Hui-Min Wen,Jing Wang,Lijiao Ao,Jun Hu

Exploring signal amplification strategies to enhance the sensitivity of lateral flow immunoassay (LFIA) is of great significance for point-of-care (POC) testing of low-concentrated targets in the field of in vitro diagnostics. Here, a highly-sensitive LFIA platform using compact and hierarchical magneto–fluorescent assemblies as both target-enrichment substrates and optical sensing labels is demonstrated. The large-pored dendritic templates are utilized for high-density incorporation of both superparamagnetic iron oxide nanoparticles (IOs) and quantum dots (QDs) within the vertical channels. The hierarchical structure is built via affinity-driven assembly of IOs and QDs from organic phase with silica surface and mercapto-organosilica intermediate layer, respectively. The sequential assembly with central–radial channels enables 3D loading of dual components and separately controlling of discrete functionalities. After the alkyl-organosilica encapsulation and silica sealing, the composite spheres exhibit high stabilities and compatibility with LFIA for procalcitonin (PCT) detection. With the assistance of liquid-phase antigen-capturing, magnetic enrichment, and fluorescence-signal amplification, a limit of detection of 0.031 ng mL −1 for PCT is achieved with a linear range from 0.012 to 10 ng mL −1 . The current LFIA is robust and validated for PCT detection in real serum, which holds great diagnostic significance for precise guidance of antibiotic therapy with POC manner.

研究领域: 即时检测 · 体外诊断 · 纳米技术 · 生物工程 · 分析化学
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
FOOD CONTROL · 2023 · IF 6

Development of broad-specific monoclonal antibody-based immunoassays for simultaneous ochratoxin screening in medicinal and edible herbs

Mengyue Guo,Jing zhang,Jianxin Lv,Tongwei Ke,Jiao Tian,Kun Miao,Yudan Wang,Dandan Kong,Haonan Ruan,Jiaoyang Luo,Meihua Yang

The frequent occurrence of ochratoxins in food and herbs poses a considerable threat to consumer and animal health. Here, we generated a broad-specificity monoclonal antibody against three ochratoxins. Concentrations for 50% inhibition (IC 50 ) for OTA, OTB, and OTC were 0.37, 0.23, and 2.24 ng/mL, respectively. In the two matrices, the proposed indirect competitive enzyme-linked immunosorbent assay (ic-ELISA) exhibited a limit of detection (LOD) of 1.5 μg/kg for OTA and 1.0 μg/kg for OTB, respectively, whereas the cut-off levels of lateral flow immunoassay (LFIA) for OTA and OTB were respectively determined to be 1 and 0.25 ng/mL. As for OTC, the LOD of ic-ELISA and cut-off concentration of LFIA were 15.5 μg/kg and 8 ng/mL for milkvetch root and 37.5 μg/kg and 16 ng/mL for ginger, respectively. The real sample detection results by ic-ELISA and LFIA methods were validated via LC-MS/MS analysis. Therefore, the developed immunoassays are useful and effective tools for high-throughput screening and rapid on-site determination of ochratoxins in complex matrices.

研究领域: 食品科学 · 毒理学 · 分析化学 · 免疫学
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
ACS Nano · 2023 · IF 17.1

Self-Assembly Multivalent Fluorescence-Nanobody Coupled Multifunctional Nanomaterial with Colorimetric Fluorescence and Photothermal to Enhance Immunochromatographic Assay

Zhiqiang Li,Wen Zhang,Qi Zhang,Peiwu Li,Xiaoqian Tang

The multimodal lateral flow immunoassay (LFIA) has provided accurate and reliable results for fast and immediate detection. Nonetheless, multimodal LFIA remains challenging to develop biosensors with high sensitivity and tolerance to matrix interference in agro-food. In this study, we developed a self-assembled multivalent fluorescence-nanobody (Nb26-EGFP-H6) with 16.5-fold and 30-fold higher affinity and sensitivity than a monovalent nanobody (Nb26). Based on the Nb26-EGFP-H6, we synthesized enhanced immune-probes Zn-CN@Nb26-EGFP-H6 by pyrolyzing and oxidizing an imidazolating zeolite framework-8 (ZIF-8) to obtain photothermal metal–carbon nanomaterials (Zn-CN) for immobilizing Nb26-EGFP-H6. The rough and porous structure of Zn-CN with a large surface area facilitates the enrichment and immobilization of antibodies. A trimodal lateral flow immunoassay (tLFIA) with colorimetric, fluorescent, and photothermal triple signal outputs was constructed for the detection of aflatoxin B1 (AFB1) in maize. Attractively, the Zn-CN-based tLFIA’s multiplex guarantees accurate and sensitive detection of AFB1, with triple signal detection limits of 0.0012 ng/mL (colorimetric signals), 0.0094 ng/mL (fluorescent signals), and 0.252 ng/mL (photothermal signals). The sensitivity of the trimode immunosensor was 628-fold and 42-fold higher than that of the original Nb26-based ELISA (IC50) and the unimodal LFIA (LOD). This work provides an idea for constructing a sensitive, tolerant matrix and efficient and accurate analytical platform for rapidly detecting AFB1 in food.

研究领域: 纳米技术 · 分析化学 · 食品安全 · 生物技术
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
ACS Nano · 2023 · IF 17.1

Pomegranate-Bionic Encapsulating Horseradish Peroxidase Using Dopamine Flexible Scaffold-Coated Multishell Porous ZIF-8 To Enhance Immunochromatographic Diagnosis

Mingxuan Song,Juanxia Xing,Huan Cai,Xin Gao,Chunyang Li,Changjin Liu,Xinmin Li,Xuhuai Fu,Shijia Ding,Wei Cheng,Rui Chen

Nanoparticle-natural enzyme complexes are receiving increasing attention as the promising signal reporters for colorimetric lateral flow immunoassay (LFIA). Nonetheless, it remains a challenge to develop the nanocomplexes with high loading efficiency, catalytic efficiency, and colorimetric signal brightness. Herein, inspired by pomegranate structure, we reported the synthesis of a colorimetric catalytic nanocomplex ((HRP@ZIF-8)3@PDA@HRP), using dopamine flexible scaffold-coated multishell porous zeolitic imidazolate framework-8 (ZIF-8) as a hierarchical scaffold to encapsulate horseradish peroxidase (HRP), and described its potential to promote an ultrasensitive colorimetric LFIA of cardiac troponin I (cTnI). (HRP@ZIF-8)3@PDA@HRP exhibited ultrahigh HRP loading efficiency and catalytic activity due to the epitaxial shell-by-shell overgrowth of porous ZIF-8 scaffold, which provided more cavities for enzyme immobilization and a diffusion path for the catalytic substrate. Furthermore, the polydopamine (PDA) layer on the (HRP@ZIF-8)3 surface both enhanced the colorimetric signal brightness and acted as a flexible scaffold to immobilize HRP, further increasing the amount of enzyme. Following integration with LFIA, the developed platform achieved an ultrasensitive colorimetric test strip assay for cTnI with pre- and postcatalytic naked-eye detection sensitivities of 0.5 ng mL–1 and 0.01 ng mL–1, respectively, which were 4/2- and 200/100-fold higher than gold nanoparticles (AuNPs)/PDA-based LFIA and comparable to chemiluminescence immunoassay. Further, the quantitative testing results of the developed colorimetric LFIA on 57 clinical serum samples agreed well with the clinical data. This work provides ideas for the design of natural enzymes-based colorimetric catalytic nanocomplex to encourage applications for the development of ultrasensitive LFIA for early diseases diagnosis.

研究领域: 材料科学 · 纳米技术 · 分析化学 · 生物传感器 · 医学诊断
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
ANALYTICAL CHEMISTRY · 2024 · IF 6.7

Afterglow Nanoprobe-Enabled Quantitative Lateral Flow Immunoassay by a Palm-Size Device for Household Healthcare

Jiuchuan Guo,Yudong Zhou,Jie Cheng,Fuli Chen,Jiahui Xu,Lirong Yang,Huifang Shi,Zhongfu An,Jinhong Guo,Xing Ma

Lateral flow immunoassay (LFIA), a classical point-of-care testing (POCT) technique, plays an important role in disease screening and healthcare monitoring. However, traditional LFIA is either designed for qualitative analysis or requires expensive equipment for quantification, limiting its use in household diagnosis. In this study, we proposed a new generation of LFIA for household health monitoring by using ultralong organic phosphorescence (UOP) nanomaterials as afterglow nanoprobes with a self-developed palm-size sensing device. The UOP nanoprobes exhibit a phosphorescence signal with a second-level lifetime, which completely avoids the interference from excitation light and biological background fluorescence. Therefore, an ultraminiaturized and low-cost UOP nanosensor was successfully designed by eliminating the complex optical path and filtering systems. We chose an inflammatory factor, C-reactive protein (CRP), for household POCT validation. The whole analysis was completed within 9 min. A limit of detection (LOD) of 0.54 ng/mL of CRP antigen was achieved with high stability and good specificity, which is comparable to laboratory instruments and fully satisfying the clinical diagnosis requirement.

CAS / MDL: 9004-32-4
研究领域: 生物医学工程 · 分析化学 · 医学诊断 · 纳米技术 · 即时检测设备
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。