文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

显示第13至13个,产品总数13个

设置提升方向
PATP
MICROCHIMICA ACTA · 2018 ·Vol. 185 ·期 2 ·1-8 · IF 5.705

A SERS-based multiple immuno-nanoprobe for ultrasensitive detection of neomycin and quinolone antibiotics via a lateral flow assay

Shi Qiaoqiao,Huang Jie,Sun Yaning,Deng Ruiguang,Teng Man,Li Qingmei,Yang Yanyan,Hu Xiaofei,Zhang Zhijun,Zhang Gaiping

The authors describe an ultrasensitive method for simultaneous detection of neomycin (NEO) and quinolones antibiotics (QNS). It is based on the use of (a) two immuno-nanoprobes (a probe for NEO and a probe for QNS), (b) surface-enhanced Raman scattering (SERS) detection, and (c), a portable lateral flow assay (LFA). The two probes consist of gold nanoparticles (AuNPs) conjugated to the Raman active molecule 4-aminothiophenol (PATP), and to monoclonal antibody against NEO (NEO mAb) or against NOR (NOR mAb). Quantitative detection of NEO and QNS was realized via SERS of the PATP-coated AuNPs captured in the test line of a LFA. Under optimized condition, the visual limits of LFA are 10 ng·mL −1 for NEO and 200 ng·mL −1 for NOR, and with LODs down to 0.37 pg·mL −1 and 0.55 pg·mL −1 by using SERS. The NEO test line is not interfered by the NEO analogues gentamycin, streptomycin and tobramycin, but the NOR test line suffers from different degrees of cross-reactivity (CR) to 12 common other QNS, the CRs ranging from 1.5% to 136%. The recoveries of NEO and NOR from spiked milk samples ranged between 86% and 121%, with relative standard deviations (RSD) from 3% to 6%. The method is highly sensitive, accurate and effective. It may be applied to simultaneous detection of NEO and 8 QNS, including NOR, enoxacin, ciprofloxacin, ofloxacin, fleroxacin, marbofloxacin, enrofloxacin, and pefloxacin. Schematic of a lateral flow assay (LFA) based on an indirect competitive model. By using two test lines, the LFA can detect the neomycin and quinolones antibiotics simultaneously. Based on the surface-enhanced Raman scattering (SERS), the LFA shows high sensitivity to antibiotics with low limit of detection.

CAS / MDL: 1193-02-8
研究领域: 分析化学 · 纳米技术 · 药物分析 · 食品安全
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。