文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

显示第13至14个,产品总数14个

设置提升方向
chronoamperometry
BIOSENSORS & BIOELECTRONICS · 2020 · IF 10.257

A novel dual signal and label-free electrochemical aptasensor for mucin 1 based on hemin/graphene@PdPtNPs

Guojuan Zhang,Zhiguang Liu,Lifang Fan,Yujie Han,Yujing Guo

A dual signal and label-free electrochemical aptasensor for mucin 1 was constructed based on hemin/ [email protected] nanocomposite ( [email protected] ). Hemin attached on the graphene surface not only improves the solubility of graphene and acts as an in-situ electrochemical probe but also exhibits excellent peroxidase-like properties to electrocatalyze the reduction of H 2 O 2 . PdPtNPs also show outstanding catalytic capacity to the reduction of H 2 O 2 and provide numerous binding sites for loading dDNA (mucin 1 aptamer and cDNA) to form the sensing interface. In the presence of mucin 1, due to the specific affinity between aptamer and mucin 1, double helix would be induced dissociation and the aptamer would be pulled off from the electrode. As a result, the electrochemical signals of hemin and H 2 O 2 were recovered. Based on these properties, the label-free and sensitive dual signal electrochemical biosensor for mucin 1 detection has been developed. The one is differential pulse voltammetry (DPV) signal of hemin and the other is chronoamperometry signal arisen from the catalytic reduction of H 2 O 2 . The linear ranges for mucin 1 were 8.0 pg mL −1 to 80 ng mL −1 and 0.8 pg mL −1 to 80 ng mL −1 with the limit of detection 2.5 pg mL −1 and 0.25 pg mL −1 by DPV and chronoamperometry, respectively. The recovery of mucin 1 in human blood serum samples was from 95.0% to 104.2%. The detection platform does not need signal labeling which greatly reduced the sophisticated and expensive procedures. The aptasensor provide a promising strategy for the determination of mucin 1 in clinical diagnostics.

研究领域: 生物传感器 · 分析化学 · 癌症诊断 · 电化学
✓ 已验证 DOI PubMed 高影响因子
查看原文 查看 PubMed
MICROCHEMICAL JOURNAL · 2022 · IF 5.304

Electrochemical biosensors based on conducting polymer composite and PAMAM dendrimer for the ultrasensitive detection of acetamiprid in vegetables

Yan Zhou,Haitao Lü,Decheng Zhang,Keke Xu,Ni Hui,Jiasheng Wang

The cumulative harm caused by pesticide residues to environmental safety and human health is enormous, and the sensitive and selective detection pesticide in very trace amounts is currently a challenge. Herein, the biosensors for the ultrasensitive detection of acetamiprid (ACE) were proposed. The conducting polymer composite of phaseoloidin doped poly(3,4-ethyloxythiophene) (PL/PEDOT) was prepared with high surface area, excellent conductivity and stability, which was followed by the functionalization with poly(amidoamine) of the third generation (PAMAM). ACE aptamers were immobilized onto the platforms (PL/PEDOT and PAMAM/PL/PEDOT) for the development of ACE aptasensors. The concentration of ACE can be measured through both the increase of differential pulse voltammetry (DPV) signal change and the increase of the chronoamperometry (CA) signal change from the reduction of hydrogen peroxide catalyzed by PL/PEDOT. The ACE aptasensor based on PAMAM/PL/PEDOT exhibited linear ranges of 0.1 pg mL −1 -10 ng mL −1 and 0.1 fg-1.0 pg mL −1 , the detection limits as low as 0.0117 pg mL −1 and 0.0355 fg mL −1 (S/N = 3) through DPV and CA, respectively. Significantly, the response sensitivity of DNA/PAMAM/PL/PEDOT/GCE was 3.11 times higher than that of DNA/PL/PEDOT/GCE (by CA mode), proving that the PAMAM dendrimer can greatly enhance the sensing performance.

研究领域: 分析化学 · 环境科学 · 生物传感器 · 农业化学
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。