文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

347,358+ SCI 论文 与阿拉丁产品引用相关
2,303,472.95 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

产品列表

视图 列表 网格

显示第265至265个,产品总数265个

设置提升方向
Attapulgite
TALANTA · 2017 · IF 4.162

Magnetic mixed hemimicelles dispersive solid-phase extraction based on ionic liquid-coated attapulgite/polyaniline-polypyrrole/Fe3O4 nanocomposites for determination of acaricides in fruit juice prior to high-performance liquid chromatography-diode array detection

Xiaoling Yang,Kexin Qiao,Fang Liu,Xiaoling Wu,Miyi Yang,Jing Li,Haixiang Gao,Sanbing Zhang,Wenfeng zhou,Runhua Lu

In this research, a novel method using magnetic mixed hemimicelles dispersive solid-phase extraction (MMHDSPE) based on C 16 mimBr-coated attapulgite/polyaniline-polypyrrole/Fe 3 O 4 (ATP/PANI-PPY/Fe 3 O 4 ) nanocomposites were investigated for enrichment and separation of three acaricides in fruit juice. In this method, we combined the simplicity and speed of dispersive solid-phase extraction, the advantages of mixed hemimicelles and the facility of the phase separation of the magnetic nanoparticles to develop a simple, rapid, sensitive, and effective method for detecting target analytes from the juice samples. ATP/PANI-PPY/Fe 3 O 4 nanocomposites were successfully synthesized using a one-pot method. The as-prepared nanocomposite sorbents were characterized by Fourier transform infrared spectra (FT-IR), X-ray diffraction (XRD), scanning electron microscopy (SEM), and transmission electron microscopy (TEM). The experimental factors affecting the extraction efficiency including the sorbent type, amount of ATP/PANI-PPY/Fe 3 O 4 nanocomposites, volume of ILs , sonication time, pH, and desorption conditions were optimized. Under the optimal conditions, good linearity was observed for all target analytes, with correlation coefficients (r 2 ) ranging from 0.9994 to 0.9999; the limits of detection (LOD) were in the range of 0.16–0.57   μg   L −1 , and the recoveries of analytes using the proposed method ranged between 88.67% and 95.10%. The sorbents exhibited excellent repeatability in the range of 1.83–4.24% in extracting the three target analytes. In addition, the intra-day and inter-day precision values were found to be in the range of 0.19–6.24% and 2.23–8.36%, respectively. The method was successfully applied to analyze fruit juice samples by rapid preconcentration of acaricides.

✓ 已验证 DOI 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。