JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES
·
2019
·
IF 2.813
Zhuowei Shen,Kaifeng He,Mingcheng Xu,Kui Zeng,Jie Pan,Fengting Ou,Jianbiao Yao,Ruwei Wang,Su Zeng
A sensitive and specific bioanalytical method of liquid chromatography-tandem mass spectrometry (LC-MS/MS) for the quantification of 6-hydroxykynurenic acid (6-HKA) in a small quantity of rat plasma has been developed and comprehensively validated. Tolbutamide (Tol) was used as the internal standard (IS). An aliquot of 50 μL rat plasma sample was deproteinized by 150 μL methanol, and then 100 μL of its supernatant was mixed with 100 μL water after centrifugation . Chromatographic separation was performed on a ZORBAX Eclipse Plus C 18 Rapid Resolution HD column (2.1 mm × 100 mm, 1.8 μm) with a gradient mobile phase consisting of water containing 2 mM ammonium formate and methanol at a flow rate of 0.2 mL/min over a total run time of 5.0 min. The mass spectrometer was operated under multiple reactions monitoring (MRM) mode with the transitions m / z 206.1 → 160.0 for 6-HKA and m/z 269.0 → 170.0 for Tol. The linear range was 2.5–250 ng/mL with the square regression coefficient (r 2 ) of 0.997. The lower limit of quantification (LLOQ) was 2.5 ng/mL (Relative Error, RE +1.6% and RSD 4.8%, n = 5). The intra- and inter-day precision and accuracy was <13.3%. The mean recovery of 6-HKA in rat plasma was between the range of 99.3–103.4%. This method was successfully applied to study the pharmacokinetics of 6-HKA in rats after oral administration at a single dose of 20.0 mg/kg and after tail intravenous injection at a single dose of 2.0 mg/kg. Pharmacokinetic parameters bioavailability, C max, oral , T max, oral , AUC 0–24h, oral , AUC 0–∞, oral , AUC 0–24h, iv and AUC 0–∞, iv were 3.96%, 152.0 ± 85.5 ng/mL, 0.4 ± 0.1 h, 340.0 ± 136.3 ng/mL ∗ h, 369.5 ± 135.0 ng/mL ∗ h, 906.6 ± 324.1 ng/mL*h and 932.9 ± 336.5 ng/mL ∗ h, respectively.
✓ 已验证
产品关联
DOI
PubMed
高影响因子
BIOMEDICAL CHROMATOGRAPHY
·
2017
·Vol. 32
·期 3
·e4126
·
IF 1.613
Fuguo Shi,Hong Pan,Yi Li,Linyan Huang,Qin Wu,Yuanfu Lu
Genipin (GP), an active metabolite of geniposide (GE), exhibits more potent pharmacological effects than its parent compound. In this paper, a sensitive LC-MS/MS method was developed and fully validated for the simultaneous determination of GE and GP in rat plasma. We found that GP degraded rapidly in rat plasma at room temperature as a result of irreversible binding with the endogenous nucleophiles in plasma. GP was stable when the sample's pH was ≤4.0. The degradation of GP in rat plasma was well prevented by immediate addition of 5% glacial acetic acid to the freshly collected plasma. The detection was performed on a tandem mass spectrometer coupled with electrospray ionization source in negative mode. Quantification was conducted by multiple reaction monitoring of the transitions [M + CH 3 COO] − m/z 447.3 → 225.3 for GE and [M − H] − m/z 225.2 → 123.1 for GP. The method exhibited high sensitivity (LLOQ 1 ng/mL for GE and 0.2 ng/mL for GP) by selecting the acetate adduct ions as the precursor ions for GE. The robust developed method was successfully applied to a pharmacokinetic study in rats after oral administration of GE.
✓ 已验证
产品关联
DOI
PubMed
高影响因子
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES
·
2024
·
IF 2.8
Zong-liang Xu,Cheng-jian Li,Xian Qian,Hu Duan,Jin Zhou,Qian-qian Zhang,Xin Dong,Liang Zhao
Antiviral treatment for COVID-19 is considered an effective tool in reducing the rate of severe cases and deaths. As of June 2023, a total of six small molecule antiviral drugs have been conditionally approved for marketing by the National Medical Products Administration (NMPA) within China. In this study, a method of HPLC-MS/MS was established and validated for the determination of six small molecule antiviral drugs in plasma using Lamivudine as an internal standard. The chromatographic separation was performed using gradient elution with an ACE 3 C 18 -PFP column (3.0 mm × 150 mm, 3 μm), and the mobile phase consisted of deionized water and acetonitrile/water (90:10, v/v), both with 10 mmol/L of ammonium acetate and 0.1 % ammonium hydroxide added. Quantitative analysis of the six small molecule drugs was carried out through selective reaction monitoring based on the positive ion spray ionization mode. The method exhibited excellent precision, accuracy, recovery, and linearity, and it was used to determine the pharmacokinetic characteristics in rats. Our work not only established a bioanalytical method for six small molecule antiviral drugs but also provided scientific references for clinical pharmacokinetic studies.
✓ 已验证
产品关联
DOI
PubMed
高影响因子
JOURNAL OF CHROMATOGRAPHY A
·
2025
·
IF 4
Yang Yang,Jin Wang,Jia Qiu,Yan Luo,Chun Yang,Shali Tang,Hui Cao,Qian Wang,Xiaojing Lai
To monitor per- and polyfluoroalkyl substances (PFAS) in food contact materials (FCMs), an LC-MS/MS method for the simultaneous detection of 35 PFAS was developed and validated in paper and plastic products. Chromatographic and mass spectrometry parameters, extraction solvents, matrix effects in details were studied. The impact of matrix effects on PFAS concentration was analyzed, revealing that the matrix enhancement effect was more significant for some PFAS with low concentrations. In order to eliminate the matrix effect and enhance detection accuracy, a straightforward pretreatment method combining methanol ultrasonic extraction with dispersive solid-phase extraction (d-SPE) was established. PFHpA, PFDA, PFTriDA, PFTeDA, PF-3,7-DMOA, HFPO-DA, PFHxS, PFHpS, PFOS, 4:2 FTS, 6:2 FTS, 8:2 FTS, 10:2 FTS, and 6:2 diPAP required further d-SPE extraction with PSA, and other substances could be directly extracted by methanol ultrasonic treatment. The recoveries of the established method for all compounds ranged from 62.40 to 135.80%, with a relative standard deviation (RSD) of 0.15% to 16.81%. The limit of quantitation was between 0.005 and 0.02 mg·kg −1 . The method was applied to detect PFAS in 119 FCMs, resulting in the identification of 15 PFAS.
✓ 已验证
产品关联
DOI
PubMed
高影响因子
Applied Food Research
·
2025
·
IF 6.2
Guodong Shan,Xiuqin Fan,Qingcheng Wang,Li Zhang,Lijun Ge,Weibo Lu,Jing Xue,Kang Chen,Zejun Wang,Qing Shen
The inappropriate use of H2 receptor antagonists (H2RAs) in functional foods (FFs) and food-medicine homology materials (FMHs) designed to enhance gastrointestinal function (IGF) presents health risks due to potential adverse effects. In this study, an analytical method that integrates Captiva EMR-Lipid (CEL) solid-phase extraction (SPE) with liquid chromatography tandem mass spectrometry (LC-MS/MS) has been developed for the detection of H2RAs (nizatidine, famotidine, cimetidine, ranitidine, and lafutidine) in these products. Through the optimization of CEL-SPE parameters, such as using 200 mg of sorbent and eluting with ACN/water (80/20, v/v), the recovery rates of H2RAs in IGF-FF and IGF-FMH ranged from 87.4 % to 94.6 % and 90.2 % to 97.1 %, respectively. The assessment of matrix effects revealed that the five H2RAs exhibit matrix suppression, necessitating the construction of matrix-matched standard curves with correlation coefficients (r 2 ) exceeding 0.9991. The detection limits ranged from 0.4 to 0.8 μg·kg −1 and the quantification limits ranged from 1.3 to 2.7 μg·kg −1 , with recovery rates spanning from 85.4 % to 97.1 % and relative standard deviations ≤ 15 %. The successful development of this technique not only helps safeguard consumer health but also provides scientific basis and technical support for market supervision, thereby preventing and addressing food safety risks.
✓ 已验证
产品关联
DOI
高影响因子
ANALYTICAL AND BIOANALYTICAL CHEMISTRY
·
2025
·
IF 3.8
Li Wenya,Gao Bingling,Yang Tao,Tang Liping,Song Dan,Li Hongmei,Sun Keqi,Xiao Peng
3,3′,5-Triiodothyronine (T3) plays a crucial role in the diagnosis and evaluation of thyroid diseases. The current reference measurement procedure (RMP) has been in place for 20 years and is widely adopted by reference laboratories around the world. To enhance the performance of the RMP, we developed and validated a simplified, SI-traceable candidate RMP specifically targeting serum total T3 (TT3) using isotope dilution-liquid chromatography with tandem mass spectrometry (ID-LC–MS/MS). Specifically, T3 reference material was employed as the standard. Compared to the RMP, our method incorporates a simplified serum cleanup process involving protein precipitation and nitrogen drying. The method validation followed ISO guidelines for measurement uncertainty assessment. Our results indicated that there was no significant conversion of T4 into metabolites during the serum pretreatment. The lower limit of the measuring interval was determined to be 0.077 nmol/L, and the regression model was linear across a range of 0.016 to 13.086 nmol/L. The imprecision of intra-assays ranged from 0.1 to 1.9%, while inter-assay imprecision ranged from 0.5 to 1.2%. The bias observed when analyzing SRM971 was between − 0.34 and − 1.65%. This candidate RMP demonstrated excellent agreement with the RMPs developed by RELA activity, showing a mean bias falling within the educational mean ratio (6%). The measurement uncertainties were 0.022 nmol/L for RELA2023A and 0.120 nmol/L for RELA2023B. In conclusion, the developed candidate RMP is traceable, reliable, and easy to operate, showing promising potential for the development of serum reference materials and the standardization of routine assays. Graphical
✓ 已验证
产品关联
DOI
PubMed
高影响因子
ACS Omega
·
2025
·
IF 4.3
Tingting Lou,Benkai Qin,Jiaqi He,Hongliu Qu,Haiyan Rong,Qunan Cheng,Weiyong Lu,Yaqin Liu,Yonghua Yu
A rapid, specific, and sensitive LC–MS/MS method for the determination of sulindac and its metabolite Su-EP-C in human EDTA-K2 plasma was developed. The method was fully validated using sulindac-d3 and Su-EP-C-d3 as internal standards. Separation was performed on a Kinetex C18 analytical column (100 Å, 50 × 2.1 mm, 5 μm). MPA consisted of 0.05% formic acid (FA) in water, while MPB comprised 0.05% FA in ACN. The flow rate was maintained at 0.300 mL/min, and the injection volume was 3 μL. Mass spectrometry conditions: ESI, positive mode, MRM. The linear range of detection was from 60.00 to 24,000.00 ng/mL for sulindac and from 30.00 to 12,000.00 ng/mL for Su-EP-C. The intra- and interbatch accuracy deviations of sulindac ranged from −5.1 to 5.0%, and the intra- and interbatch precision ranged from 3.3 to 4.2%. The intra- and interbatch accuracy of Su-EP-C ranged from −3.9 to 6.9%, and the intra- and interbatch precision ranged from 4.8 to 7.2% at all concentration levels. At a dilution of 10, the deviation for sulindac was 3.5% and the precision was 1.5%; the deviation for Su-EP-C was 2.7%, and the precision was 4.4%. The plasma matrix, at both −20 °C and −70 °C, remained stable for 52 days with 5 freeze–thaw cycles. The method was successfully applied to fasting and postprandial pharmacokinetic clinical trials of orally administered sulindac tablets.
研究领域:
药物分析
·
临床药理学
·
生物分析化学
·
质谱分析
·
药代动力学
✓ 已验证
产品关联
DOI
PubMed
高影响因子
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES
·
2025
·
IF 2.8
Bohan Liang,Yanjie Li,Lingmei Xu,Li Wang,Quankun Zhuang,Shiqi Dong,Huirong Fan
XZP-3287(bireociclib) is a novel and selective inhibitor of the cell cyclin-dependent kinases 4/6 (CDK4/6), which is primarily employed for the treatment of breast cancer in clinical trials . In this study, a novel and sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for the simultaneous determination of XZP-3287 and its metabolites XZP-5286, XZP-3584 and XZP-5736 in human plasma in accordance with international conference on harmonization of technical requirements for registration of Pharmaceuticals for Human use (ICH) guideline R3 (M10) guideline. The multiple reaction monitoring mode (MRM) of mass spectrometer was used and all compounds were monitored in electrospray ionization (ESI+) mode. The correlation coefficients (R 2 ) of all calibration curves for linear regression were greater than 0.99. The intra- and inter-day precision of XZP-3287 and its metabolites XZP-5286, XZP-3584 and XZP-5736 were determined to be 5.2 %–5.5 %, 14.9 %–10.1 %, 6.9 %–13.8 % and 7.3 %–5.6 %, and their accuracy were determined to be 5.2 %–6.0 % 6.9 %–4.4 %, 11.1 %–5.0 % and 7.4 %–5.6 %, respectively. In conclusion, a method for the simultaneous detection of the pharmacokinetic profiles of XZP-3287 and its metabolites in human plasma had been successfully developed. The results demonstrated the efficacy, sensitivity, and reliability of this method
研究领域:
药物分析
·
临床药理学
·
肿瘤学
·
质谱分析
·
药物代谢
·
生物分析化学
✓ 已验证
产品关联
DOI
PubMed
高影响因子
JOURNAL OF MASS SPECTROMETRY
·
2026
·Vol. 61
·期 8
·e70088
·
IF 2.1
Liping Yang,Bingling Gao,Tao Yang,Liping Tang,Ying Kan,Keqi Sun,Peng Xiao
Dehydroepiandrosterone sulfate (DHEAS), a crucial steroid hormone for adrenal function and pubertal development, is highly associated with related diseases. This study aims to develop and validate an isotope dilution liquid chromatography tandem mass spectrometry (ID-LC–MS/MS)-based candidate reference measurement procedure (cRMP) for quantifying serum DHEAS. Serum samples were prepared by protein precipitation with acetonitrile and separated on a reversed phase column. Assay validation was conducted under the guidance of standard documents, including C62-A, EP6-A, EP10-A3, and C50-P endorsed by the Clinical and Laboratory Standards Institute (CLSI). The cRMP was established and proven to be highly specific without significant matrix effect and able to accurately quantify DHEAS in human serum. The intra-assay and inter-assay imprecision ranged from < 0.1 to 1.0% and from 1.0 to 1.1%, respectively. Trueness was assessed by recovery rate from 99.6 to 101.2%. The limit of detection (LoD) was 0.270 nmol/L, and the lower limit of the measuring interval (LLMI) was 12.1 nmol/L. A linear correlation ranged from 7.60 to 41 858 nmol/L was observed with a correlation coefficient > 0.999. R 2 value of linear regression analysis between this method and clinical immunoassays was ≥ 0.990. The relative expanded uncertainty was 1.5%–2.5% over the concentration range of 12.1–33 043 nmol/L. This study developed an ID-LC–MS/MS-based cRMP, which provided high specificity, trueness, and precision for serum DHEAS quantification, contributing to the DHEAS measurement standardization and traceability.
✓ 已验证
产品关联
DOI
PubMed
高影响因子
ANALYTICAL AND BIOANALYTICAL CHEMISTRY
·
2026
·
IF 4.1
Guan Xinhui,Zhang Yuying,Ma Xiaoqiao,Wang Haiyan,Qiao Xiaoqiang,Gu Xiaofei
Comprehensive characterization of exosomal phospholipids is essential for understanding cancer-associated metabolic alterations and discovering potential biomarkers, but remains challenging due to their extensive structural diversity and the limited selectivity and coverage of conventional liquid chromatography-tandem mass spectrometry (LC-MS/MS) approaches. In this study, an ionic liquid-functionalized styrene-maleic anhydride copolymer brush stationary phase (Sil-BHHICl) was developed and integrated into an offline two-dimensional (2D) LC-MS/MS platform for comprehensive exosomal phospholipid profiling. The Sil-BHHICl stationary phase exhibited a hydrophilic interaction/reversed-phase mixed-mode retention mechanism and provided enhanced selectivity toward phospholipids, enabling efficient separation at both the phospholipid-class and molecular-species levels. The developed analytical platform enabled comprehensive profiling of plasma-derived exosomal phospholipids, resulting in the identification of 274 molecular species belonging to 10 phospholipid classes. Lipidomic analysis of plasma exosomes from breast cancer patients and healthy controls revealed distinct phospholipid alterations associated with breast cancer and identified five candidate biomarkers, among which LysoPC-O (16:0) exhibited the strongest discriminatory ability. Pathway enrichment analysis further indicated that the altered phospholipids were predominantly associated with glycerophospholipid metabolism, suggesting extensive lipid metabolic remodeling in breast cancer. Overall, this study establishes a mixed-mode chromatographic platform for high-coverage exosomal phospholipid profiling and demonstrates its potential for lipidomics-based biomarker discovery and investigation of disease-associated metabolic alterations. Graphical abstract
✓ 已验证
DOI
高影响因子
CLINICA CHIMICA ACTA
·
2026
·
IF 4.1
Xin-Yu Wu,Xiao-Kang Fu,Ao Li,Wei Zhang,Han-Peng Jiang,Na An,Quan-Fei Zhu,Shao-Ting Wang,Yu-Qi Feng
Background Therapeutic drug monitoring (TDM) of tacrolimus requires accurate, high-throughput methods, but conventional liquid chromatography–tandem mass spectrometry (LC-MS/MS) is limited by lengthy run times and complex sample preparation. Methods We developed a chromatography-free assay for quantification of tacrolimus in whole blood by integrating cold-induced phase separation with acoustic ejection mass spectrometry (AEMS). This workflow only requires less than 10 μL of whole blood, eliminates centrifugation, and enables direct nanoliter-scale injection into the mass spectrometer. The AEMS assay performance was validated in accordance with CLSI C62-A and ICH M10 guidelines using 62 patient samples and matrix-matched calibrators, demonstrating its suitability for high-throughput therapeutic drug monitoring. Results The AEMS assay exhibited excellent linearity (0.5–50 μg/L; R 2 = 0.9987), with a lower limit of quantification of 0.5 μg/L, which was well below clinically relevant trough concentrations. Accuracy (93.3%–100.1%) and precision (intra-day RSD: 3.7%–11.3%; inter-day RSD: 2.3%–12.4%) met regulatory acceptance criteria. Results showed strong concordance with routine LC-MS/MS (Spearman ρ = 0.972; Passing–Bablok slope = 1.100 [95% CI: 1.026–1.177]). The total analysis cycle time was less than 3 s per sample, enabling a throughput exceeding 1000 samples per hour theoretically. Conclusion This study establishes the first chromatography-free mass spectrometry platform validated for clinical TDM of TAC. By integrating ultra-high throughput capability, minimal sample consumption, and robust analytical performance, the AEMS workflow offers a transformative analytical solution for high-demand clinical environments, including transplant centers and pediatric monitoring settings.
✓ 已验证
产品关联
DOI
PubMed
高影响因子
JOURNAL OF CHROMATOGRAPHIC SCIENCE
·
2025
·Vol. 63
·期 10
·
IF 1.3
Zheng Jun-tao,Kong Jia-he,Yang Ting,Wang Xue-ding,Guan Shao-xing,Guan Yan-ping,Huang Min,Gao Xiang,Chao Kang,Zhu Xia
Deoxythioguanosine (dTG), incorporated into DNA as DNA-TG, is considered a more relevant thiopurine metabolite than erythrocyte thioguanine nucleotides, as erythrocytes are not the drug target. We established a simple and sensitive liquid chromatography–tandem mass spectrometry method to detect dTG in human blood nucleated cell DNA and validated its clinical applicability in Chinese patients with inflammatory bowel disease to improve individualized thiopurine treatment. dTG was released from 1 μg DNA in a single hydrolysis step, separated by the X-Terra RP18 column and quantified by tandem mass spectrometry with 2′- Deoxyguanosine-13C,15N2 as the internal standard. The calibration curve covered eight concentration levels (0.125–25 ng/mL) with the correlation coefficients r2 ≥ 0.99. The intra- and inter-assay variability was achieved less than 9.9%. This method was employed in a study where a total of 125 inflammatory bowel disease patients with a median DNA-TG level of 279.7 fmol/μg DNA (interquartile range 183.5 ~ 410.6 fmol/μg DNA). Nucleoside diphosphate-linked moiety X-type motif 15 variant carriers (*2, *3, *5, *6) showed significantly higher DNA-TG/dose and DNA-TG/erythrocyte thioguanine nucleotides ratios than wild-type patients (P = 0.0023, P = 0.0001). In summary, this method was simple and stable to detect dTG in DNA, which may act as a promising biomarker predicting the toxicity and efficacy in patients treated with thiopurine.
✓ 已验证
DOI
高影响因子